موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
غرف الأبحاث معدات قطع الغيار

UV مصباح أنبوب

A double-ended clear-quartz UV-C discharge tube for restoring the germicidal source inside compatible enclosed cleanroom and air-treatment equipment.
  • Clear Fused-Quartz Envelope
  • Double-Ended G13 Bi-Pin Caps
  • Low-Pressure UV-C Discharge
  • Single-Tube Service Replacement
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This UV lamp tube is a replaceable low-pressure mercury discharge source for compatible enclosed air, surface and equipment-disinfection systems. One transparent T8 quartz envelope carries an electrode assembly at each end, while two white ceramic G13 caps provide four fixed contact pins for mechanical seating and electrical connection. The lamp contains no holder, reflector, ballast or enclosure, so tube length, diameter, wattage, operating current and control-gear type are matched to the existing unit before installation. Its germicidal output is invisible during normal operation; the replacement is therefore intended only for equipment that prevents unshielded personnel exposure and safely controls lamp operation.

الخصائص الرئيسية

The clear fused-quartz envelope transmits the intended short-wave output while retaining the familiar straight T8 geometry used by many professional disinfection systems.

Two medium bi-pin end caps provide a defined four-contact interface that supports quick tube removal without replacing the permanent fixture body.

Separate electrode structures at the two ends sustain the low-pressure discharge along one continuous tube rather than using LEDs or a visible-light phosphor coating.

A single bare-lamp format allows maintenance teams to replace only the spent radiation source when the existing holders, ballast and protective enclosure remain serviceable.

مخاوف المنتج للعملاء

A tube that appears mechanically similar can still be incompatible with the installed holders or ballast; safe replacement requires the physical, electrical and shielding conditions to match as one system.

A lamp with the wrong overall length or pin spacing will not seat squarely in the existing G13 holders.Base-face length, overall pin-tip length, tube diameter and two-pin geometry are checked against the removed tube before selection.
Incorrect wattage, operating current or ballast type can prevent stable ignition and accelerate electrode wear.The replacement electrical rating is matched to the installed magnetic or electronic control gear rather than selected by appearance alone.
Quartz contamination and fingerprints can create local hot spots or reduce useful transmission after handling.The tube is handled by its ceramic caps or with clean gloves and the quartz surface is cleaned using a compatible lint-free method before operation.
An exposed operating UV-C source can injure eyes and skin even though the radiation is not visibly bright.The lamp is operated only inside a closed shielded unit with functional covers, door interlocks and power isolation for servicing.

تطبيقات نموذجية

Enclosed cleanroom air-disinfection modulesUV-C sections in air-handling and duct equipmentCompatible transfer-chamber irradiation systemsShielded laboratory and process-equipment sterilization units

المعلمات الفنية

The ranges below describe common double-ended T8/G13 low-pressure UV-C replacement lamps; the exact electrical rating and tube length are selected for the existing disinfection equipment.

المواد الأساسيةClear fused-quartz low-pressure mercury and rare-gas discharge envelope with internal electrodes and white ceramic G13 end caps
سمك اللوحة0.8-1.5 mm representative quartz tube-wall thickness
العرض الفعال26-28 mm nominal T8 tube outside diameter
الحد الأقصى الطولUp to 1214 mm overall pin-tip length for representative long T8 versions
الصلب يواجه سمك0 mm steel facing; the radiation envelope is clear quartz glass
الكثافة الأساسيةApproximately 2200-2203 kg/m³ for representative fused quartz
الموصلية الحراريةApproximately 1.38 W/(m·K) for representative fused quartz at room temperature
إنهاء السطحClear polished quartz tube, plain white ceramic caps and neutral nickel-colored contact pins
نوع المشتركDouble-ended G13 medium bi-pin connection with one ceramic cap and two fixed parallel pins at each end
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Tube length and wattage matched to the existing equipmentStandard-output or high-output electrical configurationOzone-suppressing or ozone-producing quartz transmission optionCompatible magnetic-ballast or electronic-ballast version

Planning a UV Lamp Tube specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.