موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات إزالة التلوث للموظفين والمواد

الضغط الإيجابي النظيف نقل تمرير مربع

A filtered-supply pass box maintained above adjacent pressure to reduce inward contamination towards sensitive payloads.
  • Positive Chamber Bias
  • Filtered Supply Air
  • Controlled Relief Path
  • Timed Clean-Air Purge
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The positive-pressure transfer pass box supplies more filtered air than leaves through its controlled relief path, moving small leakage outwards instead of drawing room particles towards the payload. A fan, diffuser and pressure sensor maintain the selected chamber condition. Receiving-side access can be delayed until a purge and pressure recovery have completed.

الخصائص الرئيسية

A filtered supply fan maintains a small positive pressure bias.

A defined relief path avoids reliance on door-gap leakage.

A full-width diffuser distributes clean air across trays and containers.

Pressure indication supports operational checks before release.

A timed purge clears loading-side air before clean-side access.

مخاوف المنتج للعملاء

Payload protection requires outward leakage control without excessive door force or uncontrolled airflow to adjacent rooms.

Room particles enter through minor gasket imperfections.Filtered positive bias drives leakage outward from the protected payload zone.
High pressure strains latches and complicates closing.A controlled relief path limits chamber pressure rise.
A narrow jet bypasses the load and leaves corners stagnant.A broad diffuser spreads supply air over the chamber.
The receiving door opens before loading-side air is displaced.A purge timer and pressure permissive control release.

تطبيقات نموذجية

Sterile component protectionOptics and sensor transferMicroelectronics materialsMedical-device assembly

المعلمات الفنية

Representative clean-air construction ranges for a positive-pressure transfer pass box are shown below.

المواد الأساسيةSUS 304 or SUS 316L chamber with variable-speed filtered supply fan, diffuser and relief path
سمك اللوحة80-150 mm supply-plenum and double-wall construction
العرض الفعال500-1200 mm clear transfer width
الحد الأقصى الطولUp to 1500 mm chamber depth
الصلب يواجه سمك1.0-1.5 mm stainless-steel facing
الكثافة الأساسية35-40 kg/m³ polyurethane insulation around supply and relief plenums
الموصلية الحرارية0.022-0.028 W/(m·K) for polyurethane plenum insulation
إنهاء السطحBrushed stainless chamber with smooth diffuser and removable payload shelf
نوع المشتركSealed cabinet seams with interlocked compression doors, gasketed filter frame and relief connection
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Typical +10 to +30 Pa pressure rangeH13 or H14 supply filterConstant-pressure EC fan controlFiltered or ducted relief connection

Planning a Positive-Pressure Clean Transfer Pass Box specification?