Caja de transferencia limpia de presión positiva
A filtered-supply pass box maintained above adjacent pressure to reduce inward contamination towards sensitive payloads.
- Positive Chamber Bias
- Filtered Supply Air
- Controlled Relief Path
- Timed Clean-Air Purge
Introducción del producto
The positive-pressure transfer pass box supplies more filtered air than leaves through its controlled relief path, moving small leakage outwards instead of drawing room particles towards the payload. A fan, diffuser and pressure sensor maintain the selected chamber condition. Receiving-side access can be delayed until a purge and pressure recovery have completed.
Características clave
A defined relief path avoids reliance on door-gap leakage.
A full-width diffuser distributes clean air across trays and containers.
Pressure indication supports operational checks before release.
A timed purge clears loading-side air before clean-side access.
Preocupaciones del producto del cliente
Payload protection requires outward leakage control without excessive door force or uncontrolled airflow to adjacent rooms.
Room particles enter through minor gasket imperfections.Filtered positive bias drives leakage outward from the protected payload zone.
High pressure strains latches and complicates closing.A controlled relief path limits chamber pressure rise.
A narrow jet bypasses the load and leaves corners stagnant.A broad diffuser spreads supply air over the chamber.
The receiving door opens before loading-side air is displaced.A purge timer and pressure permissive control release.
Aplicaciones típicas
Sterile component protectionOptics and sensor transferMicroelectronics materialsMedical-device assembly
Parámetros técnicos
Representative clean-air construction ranges for a positive-pressure transfer pass box are shown below.
| Materiales Core | SUS 304 or SUS 316L chamber with variable-speed filtered supply fan, diffuser and relief path |
|---|---|
| Panel de espesor | 80-150 mm supply-plenum and double-wall construction |
| Ancho efectivo | 500-1200 mm clear transfer width |
| Longitud máxima | Up to 1500 mm chamber depth |
| Acero frente a espesor | 1.0-1.5 mm stainless-steel facing |
| Densidad Core | 35-40 kg/m³ polyurethane insulation around supply and relief plenums |
| Conductividad térmica | 0.022-0.028 W/(m·K) for polyurethane plenum insulation |
| Superficie acabada | Brushed stainless chamber with smooth diffuser and removable payload shelf |
| Tipo conjunto | Sealed cabinet seams with interlocked compression doors, gasketed filter frame and relief connection |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Typical +10 to +30 Pa pressure rangeH13 or H14 supply filterConstant-pressure EC fan controlFiltered or ducted relief connection
Planning a Positive-Pressure Clean Transfer Pass Box specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.