موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

Occupancy الاستشعار

A low-profile ceiling or wall sensor that detects room use for lighting control, airflow setback and occupancy status without requiring user contact.
  • PIR or Dual-Technology Detection
  • Low-Profile Ceiling Housing
  • Adjustable Time Delay
  • Lighting and HVAC Outputs
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The cleanroom occupancy sensor detects motion or presence using passive infrared, ultrasonic or combined technology. A smooth, low-profile housing limits exposed ledges while the optical lens covers the selected room area. Adjustable sensitivity, timeout and daylight interaction prevent brief absence from switching controlled systems too aggressively. Dry-contact, low-voltage or network output can command lighting, signal room-use status or request a defined HVAC setback mode while critical minimum ventilation remains under the primary airflow controls.

الخصائص الرئيسية

PIR or dual-technology sensing adapts to room size and expected occupant movement.

A shallow sealed-looking enclosure suits clean ceilings and exposed cleanroom walls.

Configurable timeout avoids rapid switching during short periods of limited movement.

Separate lighting and occupancy outputs support coordinated but independent control actions.

مخاوف المنتج للعملاء

Occupancy sensing must cover the actual work area without reacting through doorways or reducing critical cleanroom ventilation below safe minimums.

A sensor turns lights off while a seated operator makes little movement.Dual-technology detection and suitable sensitivity improve presence recognition.
Movement in the corridor triggers an empty cleanroom.Coverage masking and considered mounting keep the detection field inside the intended room.
A short absence causes unnecessary airflow and lighting cycling.Adjustable delay holds the occupied state through brief departures.
An occupancy command overrides the minimum cleanroom air-change requirement.The sensor requests only a defined setback mode while minimum airflow limits remain in the HVAC controller.

تطبيقات نموذجية

Occupancy-based cleanroom lighting controlAirflow setback requestsLaboratory occupancy statusClean corridor lighting

المعلمات الفنية

Typical materials and dimensions for a low-profile cleanroom occupancy sensor are shown below.

المواد الأساسيةPyroelectric PIR element with Fresnel lens in flame-retardant polycarbonate housing
سمك اللوحة30-55 mm sensor depth
العرض الفعال90-140 mm sensor diameter or width
الحد الأقصى الطولUp to 160 mm housing dimension
الصلب يواجه سمك0 mm; non-metallic ceiling or wall enclosure
الكثافة الأساسية1180-1220 kg/m³ for polycarbonate housing
الموصلية الحرارية0.19-0.22 W/(m·K) for polycarbonate enclosure material
إنهاء السطحMatte white low-profile housing with translucent white optical lens
نوع المشتركTwist-lock ceiling base or wall bracket with pluggable control terminal
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

PIR or dual-technology sensingCeiling or wall mountingDry contact or network outputDaylight hold-off input

Planning a Occupancy Sensor specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat