A fully welded ceiling housing that secures a terminal HEPA or ULPA filter against a continuous sealed seat and preserves room-side service access.
  • Fully Welded Air Path
  • Gasket or Gel Filter Seat
  • Room-Side Clamping
  • Aerosol Test Connections
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The cleanroom HEPA terminal housing is the pressure-containing enclosure behind a final ceiling filter. Its welded stainless-steel or coated-steel shell includes the duct inlet, filter seal surface, clamping mechanism and service test ports but allows the diffuser face and filter type to be selected separately. A smooth interior avoids exposed acoustic material and makes the upstream chamber accessible for cleaning when the filter is removed. The housing can serve supply or extract terminals and can be integrated into modular, walkable or gypsum ceilings with a matching perimeter frame.

الخصائص الرئيسية

Continuously welded seams eliminate folded casing joints that could become untreated-air bypass paths.

Adjustable room-side clamps distribute loading around gasket-seal or gel-seal filter frames.

Separate aerosol injection, upstream sampling and pressure ports support repeatable filter checks.

Multiple ceiling frames allow the same housing concept to fit T-grid, panel or hard-ceiling construction.

مخاوف المنتج للعملاء

The housing must protect the final-filter seal from duct pressure, ceiling movement and repeated filter changes while retaining a clean internal air path.

Folded casing seams leak upstream air around the filter.A continuously welded shell creates one pressure-tight path from the duct inlet to the seal seat.
Uneven clamps distort the filter frame and compress one side of the gasket more than another.Distributed adjustable retainers apply balanced room-side loading around the filter perimeter.
Testing hoses and instruments cannot connect without removing the diffuser.Accessible capped ports separate aerosol, sample and pressure functions at the terminal face.
A housing flange leaves ledges around a hard cleanroom ceiling.Flush perimeter frame variants close neatly to T-grid, sandwich-panel or sealed gypsum ceilings.

تطبيقات نموذجية

Terminal filtration above sterile manufacturing roomsFinal exhaust filtration in containment support areasHospital clean ventilation ceilingsLaboratory HEPA supply branchesMicroelectronics cleanroom ceiling grids

المعلمات الفنية

Representative material and size ranges for welded cleanroom terminal filter housings are listed below.

المواد الأساسيةFully welded 304 stainless steel or epoxy-coated steel with stainless filter clamps and polymer seal channel
سمك اللوحة0.8–1.5 mm welded housing panels
العرض الفعال305–610 mm nominal terminal filter width
الحد الأقصى الطولUp to 1220 mm for rectangular ceiling housings
الصلب يواجه سمك0.8–1.5 mm housing sheet and 1.5–2.0 mm perimeter flange
الكثافة الأساسيةApproximately 8000 kg/m³ for 304 stainless-steel housing construction
الموصلية الحراريةApproximately 14–16 W/(m·K) for 304 stainless-steel housing construction
إنهاء السطحSmooth bead-blasted or electropolished stainless steel, or white epoxy powder coating
نوع المشتركContinuously welded shell with gasket- or gel-seal filter channel and flanged duct inlet
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

304 or 316L stainless-steel constructionGasket-seal or liquid-gel filter interfaceTop or side duct connectionT-grid, panel-ceiling or hard-ceiling perimeter frame