Cleanroom HEPA logement terminal
- Fully Welded Air Path
- Gasket or Gel Filter Seat
- Room-Side Clamping
- Aerosol Test Connections
Introduction de produit
The cleanroom HEPA terminal housing is the pressure-containing enclosure behind a final ceiling filter. Its welded stainless-steel or coated-steel shell includes the duct inlet, filter seal surface, clamping mechanism and service test ports but allows the diffuser face and filter type to be selected separately. A smooth interior avoids exposed acoustic material and makes the upstream chamber accessible for cleaning when the filter is removed. The housing can serve supply or extract terminals and can be integrated into modular, walkable or gypsum ceilings with a matching perimeter frame.
Key Features
Adjustable room-side clamps distribute loading around gasket-seal or gel-seal filter frames.
Separate aerosol injection, upstream sampling and pressure ports support repeatable filter checks.
Multiple ceiling frames allow the same housing concept to fit T-grid, panel or hard-ceiling construction.
Préoccupations du client produit
The housing must protect the final-filter seal from duct pressure, ceiling movement and repeated filter changes while retaining a clean internal air path.
Les applications typiques
Paramètres techniques
Representative material and size ranges for welded cleanroom terminal filter housings are listed below.
| Matériaux de base | Fully welded 304 stainless steel or epoxy-coated steel with stainless filter clamps and polymer seal channel |
|---|---|
| Panneau épaisseur | 0.8–1.5 mm welded housing panels |
| Largeur effective | 305–610 mm nominal terminal filter width |
| Longueur maximale | Up to 1220 mm for rectangular ceiling housings |
| Acier face épaisseur | 0.8–1.5 mm housing sheet and 1.5–2.0 mm perimeter flange |
| Densité Core | Approximately 8000 kg/m³ for 304 stainless-steel housing construction |
| Conductivité thermique | Approximately 14–16 W/(m·K) for 304 stainless-steel housing construction |
| surface finie | Smooth bead-blasted or electropolished stainless steel, or white epoxy powder coating |
| Type joint | Continuously welded shell with gasket- or gel-seal filter channel and flanged duct inlet |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Cleanroom HEPA Terminal Housing specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien