Air-to-air لوحة وحدة استرداد الحرارة
- Four-Port Cabinet Layout
- Formed Aluminum Plate Core
- Dual-Side Service Access
- Drain and Bypass Options
مقدمة المنتج
The air-to-air plate heat recovery unit combines a formed aluminum plate core, four duct connections and separate outdoor/supply and return/exhaust chambers inside one insulated galvanized-steel cabinet. Corrugated plates create alternating passages that transfer sensible heat across the metal surface, while internal folds, seals and gaskets minimize air leakage between the two paths. Removable access panels expose the filters, exchanger faces and condensate section for inspection. A sloped drain pan and optional bypass damper support wet operation, free cooling and cold-weather control without dismantling the ductwork.
الخصائص الرئيسية
Corrugated aluminum plates and mechanically folded, sealed edges provide useful transfer area while limiting internal leakage.
Full-size access panels and upstream filter rails keep both exchanger faces reachable for inspection and cleaning.
A sloped condensate section accepts a trapped drain, while an optional bypass path supports economizer and frost-control modes.
مخاوف المنتج للعملاء
A complete plate-recovery cabinet must control leakage direction, drainage, frost and maintenance access while fitting four connected air paths into a compact plant-space footprint.
تطبيقات نموذجية
المعلمات الفنية
Typical construction ranges for a complete compact plate heat recovery cabinet are listed below.
| المواد الأساسية | Formed aluminum plate core in an insulated galvanized-steel cabinet with separate outdoor/supply and return/exhaust chambers |
|---|---|
| سمك اللوحة | 30–50 mm insulated cabinet and removable access-panel construction |
| العرض الفعال | 1700–2200 mm overall cabinet width for common compact configurations |
| الحد الأقصى الطول | Up to 1490 mm overall cabinet depth in the airflow-connection direction |
| الصلب يواجه سمك | 0.8–1.2 mm galvanized or zinc-magnesium-coated cabinet skins |
| الكثافة الأساسية | 2700 kg/m³ aluminum plate material |
| الموصلية الحرارية | Approximately 205 W/(m·K) for the aluminum heat-transfer plates |
| إنهاء السطح | Mill-finish or epoxy-coated aluminum core with powder-coated or zinc-magnesium-coated cabinet surfaces |
| نوع المشترك | Gasketed four-port cabinet with internally sealed crossflow or counterflow plate pack, removable access panels and drain pan |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Air-to-Air Plate Heat Recovery Unit specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية