หน่วยกู้คืนความร้อนแบบ Air-to-Air Plate
- Four-Port Cabinet Layout
- Formed Aluminum Plate Core
- Dual-Side Service Access
- Drain and Bypass Options
การแนะนําสินค้า
The air-to-air plate heat recovery unit combines a formed aluminum plate core, four duct connections and separate outdoor/supply and return/exhaust chambers inside one insulated galvanized-steel cabinet. Corrugated plates create alternating passages that transfer sensible heat across the metal surface, while internal folds, seals and gaskets minimize air leakage between the two paths. Removable access panels expose the filters, exchanger faces and condensate section for inspection. A sloped drain pan and optional bypass damper support wet operation, free cooling and cold-weather control without dismantling the ductwork.
คุณสมบัติที่สําคัญ
Corrugated aluminum plates and mechanically folded, sealed edges provide useful transfer area while limiting internal leakage.
Full-size access panels and upstream filter rails keep both exchanger faces reachable for inspection and cleaning.
A sloped condensate section accepts a trapped drain, while an optional bypass path supports economizer and frost-control modes.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
A complete plate-recovery cabinet must control leakage direction, drainage, frost and maintenance access while fitting four connected air paths into a compact plant-space footprint.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
Typical construction ranges for a complete compact plate heat recovery cabinet are listed below.
| วัสดุหลัก | Formed aluminum plate core in an insulated galvanized-steel cabinet with separate outdoor/supply and return/exhaust chambers |
|---|---|
| ความหนาของแผง | 30–50 mm insulated cabinet and removable access-panel construction |
| ความกว้างที่มีประสิทธิภาพ | 1700–2200 mm overall cabinet width for common compact configurations |
| ความยาวสูงสุด | Up to 1490 mm overall cabinet depth in the airflow-connection direction |
| ความหนาของเหล็กหันหน้า | 0.8–1.2 mm galvanized or zinc-magnesium-coated cabinet skins |
| ความหนาแน่นหลัก | 2700 kg/m³ aluminum plate material |
| การนําความร้อน | Approximately 205 W/(m·K) for the aluminum heat-transfer plates |
| เสร็จสิ้นพื้นผิว | Mill-finish or epoxy-coated aluminum core with powder-coated or zinc-magnesium-coated cabinet surfaces |
| ประเภทร่วม | Gasketed four-port cabinet with internally sealed crossflow or counterflow plate pack, removable access panels and drain pan |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Planning a Air-to-Air Plate Heat Recovery Unit specification?
ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

ภาษาอังกฤษ
ภาษาเยอรมัน
ภาษาอาหรับ
ฝรั่งเศส
ภาษาอินโดนีเซีย
ภาษาญี่ปุ่น
ภาษาเกาหลี
ภาษามาเลย์
ภาษาโปรตุเกส
ภาษารัสเซีย
ภาษาสเปน
ภาษาไทยปัจจุบัน
ภาษาตุรกี
ภาษาเวียดนาม