Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Thiết bị xử lý không khí và HVAC phòng sạch

Đơn vị phục hồi nhiệt tấm không khí-không khí

A complete four-port heat-recovery cabinet that routes outdoor and exhaust air through separate formed-aluminum passages with service, filtration, drainage and bypass provisions.
  • Four-Port Cabinet Layout
  • Formed Aluminum Plate Core
  • Dual-Side Service Access
  • Drain and Bypass Options
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The air-to-air plate heat recovery unit combines a formed aluminum plate core, four duct connections and separate outdoor/supply and return/exhaust chambers inside one insulated galvanized-steel cabinet. Corrugated plates create alternating passages that transfer sensible heat across the metal surface, while internal folds, seals and gaskets minimize air leakage between the two paths. Removable access panels expose the filters, exchanger faces and condensate section for inspection. A sloped drain pan and optional bypass damper support wet operation, free cooling and cold-weather control without dismantling the ductwork.

Các tính năng chính

A four-port casing organizes outdoor, supply, return and exhaust connections for direct integration into a balanced ventilation layout.

Corrugated aluminum plates and mechanically folded, sealed edges provide useful transfer area while limiting internal leakage.

Full-size access panels and upstream filter rails keep both exchanger faces reachable for inspection and cleaning.

A sloped condensate section accepts a trapped drain, while an optional bypass path supports economizer and frost-control modes.

Các mối quan tâm về sản phẩm của khách hàng

A complete plate-recovery cabinet must control leakage direction, drainage, frost and maintenance access while fitting four connected air paths into a compact plant-space footprint.

An unfavorable pressure balance can drive residual internal leakage toward the clean supply-air path.Gasketed partitions and sealed plate folds minimize leakage, while maintaining the clean side at the higher pressure directs any residual leakage toward exhaust.
Water retained below the exhaust-side plate face restricts airflow and can contaminate the cabinet floor.Correct core orientation, a sloped stainless drain pan and a properly trapped outlet remove condensate from the wet section.
Winter frost progressively blocks narrow plate channels and upsets the intended supply-to-exhaust balance.A controlled bypass, upstream preheat or staged airflow response keeps the exhaust-side leaving condition above the selected frost limit.
A fixed cabinet installed between four ducts can make filters and plate faces difficult to reach.Removable service panels on the selected access side expose filter tracks, drain components and both faces of the recovery core.

Các ứng dụng điển hình

Laboratory outdoor and general exhaust-air recoveryPharmaceutical support-area ventilationMedical-device manufacturing HVACClean corridors and packaging roomsIndustrial ventilation requiring separated air streams

Thông số kỹ thuật

Typical construction ranges for a complete compact plate heat recovery cabinet are listed below.

Vật liệu lõiFormed aluminum plate core in an insulated galvanized-steel cabinet with separate outdoor/supply and return/exhaust chambers
Độ dày bảng điều khiển30–50 mm insulated cabinet and removable access-panel construction
Chiều rộng hiệu quả1700–2200 mm overall cabinet width for common compact configurations
Chiều dài tối đaUp to 1490 mm overall cabinet depth in the airflow-connection direction
Thép đối mặt với độ dày0.8–1.2 mm galvanized or zinc-magnesium-coated cabinet skins
Mật độ lõi2700 kg/m³ aluminum plate material
Độ dẫn nhiệtApproximately 205 W/(m·K) for the aluminum heat-transfer plates
Kết thúc bề mặtMill-finish or epoxy-coated aluminum core with powder-coated or zinc-magnesium-coated cabinet surfaces
Loại khớp nốiGasketed four-port cabinet with internally sealed crossflow or counterflow plate pack, removable access panels and drain pan
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Crossflow or counterflow aluminum plate coreStandard or epoxy-coated exchanger surfacesInternal bypass damper with actuatorLeft-hand or right-hand service access with condensate drain

Planning a Air-to-Air Plate Heat Recovery Unit specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ