An extended modular passage that exposes walking personnel to successive filtered-air jet zones, reducing queues at high-volume cleanroom entrances.
- Continuous Walking Route
- Sequential Cleaning Bays
- Scalable Tunnel Length
- Shift-Change Throughput
Ürün tanıtımı
The tunnel arranges a sequence of cleaning bays so operators continue walking while receiving repeated directional airflow. Each bay can contain its own blower, filter, nozzle wall and low-level return route, helping maintain coverage through the complete passage. Modular sections allow the cleaning distance to suit planned walking speed and entry volume.
Ana Özellikler
Dedicated fan-filter modules avoid a long common pressure path.
Low-level returns run continuously along the tunnel to remove released particles.
Panelised bay sections make it possible to extend the passage in stages.
One-way indicators can support orderly high-volume personnel flow.
Müşteri Ürün Sorunları
A continuous system must give personnel sufficient exposure time without allowing cleaning airflow to decay at the far end of the route.
Fast walkers receive too little cleaning exposure.Tunnel length and active-zone count can be selected for the planned walking speed.
A central blower loses pressure over a long passage.Each bay uses a short dedicated pressure loop with its own fan and final filter.
Released dust travels toward the clean exit with continuous traffic.Distributed returns remove contamination within each cleaning bay.
A long enclosure is difficult to bring into an existing building.Panelised modules can be transported separately and joined at the installation location.
Tipik uygulamalar
Semiconductor shift entryLarge electronics plantsPharmaceutical campus gowningHigh-volume food hygiene entrances
Teknik parametreler
Common modular construction ranges for a walk-through personnel tunnel are listed below.
| Temel malzemeler | Repeated powder-coated steel cleaning bays with centrifugal fans, H13 HEPA filters and adjustable stainless nozzles |
|---|---|
| Panel kalınlığı | 50 mm insulated modular wall sections |
| Effective Width (Etkili Genişlik) | 900-1500 mm clear walking passage width |
| Maksimum uzunluk | Up to 10000 mm assembled tunnel length using repeated modules |
| Çelik yüz yüze kalınlığı | 1.0-1.2 mm formed steel facing with reinforced module junctions |
| Core Density (Çekirdek Yoğunluğu) | 45-65 kg/m³ composite insulation and acoustic infill |
| Termal İletkenlik | 0.029-0.038 W/(m·K) for the selected modular panel core |
| Yüzey bitirme | Continuous white cleanroom powder coating with stainless wear trim |
| Ortak tip | Gasketed bolted tunnel-bay joints with aligned nozzle plenums and sealed return channels |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Two to ten cleaning modulesContinuous or zoned fan operationOne-way traffic indicatorsEmergency side-exit modules
Planning a Walk-Through Cleanroom Air Shower Tunnel specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca