Equipement de décontamination du personnel et du matériel
Tunnel de douche à air de salle blanche
An extended modular passage that exposes walking personnel to successive filtered-air jet zones, reducing queues at high-volume cleanroom entrances.
- Continuous Walking Route
- Sequential Cleaning Bays
- Scalable Tunnel Length
- Shift-Change Throughput
Introduction de produit
The tunnel arranges a sequence of cleaning bays so operators continue walking while receiving repeated directional airflow. Each bay can contain its own blower, filter, nozzle wall and low-level return route, helping maintain coverage through the complete passage. Modular sections allow the cleaning distance to suit planned walking speed and entry volume.
Key Features
Dedicated fan-filter modules avoid a long common pressure path.
Low-level returns run continuously along the tunnel to remove released particles.
Panelised bay sections make it possible to extend the passage in stages.
One-way indicators can support orderly high-volume personnel flow.
Préoccupations du client produit
A continuous system must give personnel sufficient exposure time without allowing cleaning airflow to decay at the far end of the route.
Fast walkers receive too little cleaning exposure.Tunnel length and active-zone count can be selected for the planned walking speed.
A central blower loses pressure over a long passage.Each bay uses a short dedicated pressure loop with its own fan and final filter.
Released dust travels toward the clean exit with continuous traffic.Distributed returns remove contamination within each cleaning bay.
A long enclosure is difficult to bring into an existing building.Panelised modules can be transported separately and joined at the installation location.
Les applications typiques
Semiconductor shift entryLarge electronics plantsPharmaceutical campus gowningHigh-volume food hygiene entrances
Paramètres techniques
Common modular construction ranges for a walk-through personnel tunnel are listed below.
| Matériaux de base | Repeated powder-coated steel cleaning bays with centrifugal fans, H13 HEPA filters and adjustable stainless nozzles |
|---|---|
| Panneau épaisseur | 50 mm insulated modular wall sections |
| Largeur effective | 900-1500 mm clear walking passage width |
| Longueur maximale | Up to 10000 mm assembled tunnel length using repeated modules |
| Acier face épaisseur | 1.0-1.2 mm formed steel facing with reinforced module junctions |
| Densité Core | 45-65 kg/m³ composite insulation and acoustic infill |
| Conductivité thermique | 0.029-0.038 W/(m·K) for the selected modular panel core |
| surface finie | Continuous white cleanroom powder coating with stainless wear trim |
| Type joint | Gasketed bolted tunnel-bay joints with aligned nozzle plenums and sealed return channels |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Two to ten cleaning modulesContinuous or zoned fan operationOne-way traffic indicatorsEmergency side-exit modules
Planning a Walk-Through Cleanroom Air Shower Tunnel specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien