Temiz Oda Tekrar Dolaşım Havası Birimi (RCU)
- Return-Air Recirculation
- Optional Cooling Coil
- EC Volume Control
- Integrated Prefilter and HEPA
Ürün tanıtımı
The cleanroom recirculation air unit draws room return air through a washable prefilter, passes it across an optional chilled-water coil and drives it through a HEPA or ULPA final filter. Fan, coil, condensate tray and controls are contained in a serviceable vertical cabinet, reducing the duct length required for a local clean zone. Temperature sensors can modulate the coil valve independently of EC fan speed so thermal load and cleanliness airflow are addressed separately. Supply may discharge through a front diffuser or connect to a short ceiling plenum serving adjacent work areas.
Ana Özellikler
The optional chilled-water coil removes local sensible heat without sending all recirculated air back to a remote AHU.
Separate EC fan and valve control allows airflow volume and temperature response to be tuned independently.
A sloped stainless condensate tray provides a defined drainage path beneath the cooling section.
Müşteri Ürün Sorunları
High recirculation rates and concentrated equipment heat can overload distant ductwork even when the central make-up air system is correctly sized.
Tipik uygulamalar
Teknik parametreler
Typical enclosure and filtration ranges for a local cleanroom recirculation unit are listed below.
| Temel malzemeler | EC centrifugal fan, optional copper-aluminium cooling coil, washable prefilter and micro-glass HEPA or ULPA pack |
|---|---|
| Panel kalınlığı | 550-900 mm cabinet depth |
| Effective Width (Etkili Genişlik) | 700-1400 mm serviceable cabinet width |
| Maksimum uzunluk | Up to 2400 mm overall vertical cabinet height |
| Çelik yüz yüze kalınlığı | 1.0-1.5 mm powder-coated steel casing with 1.0-1.5 mm stainless wet-section liner |
| Core Density (Çekirdek Yoğunluğu) | Approximately 40-60 kg/m³ density for the closed-cell cabinet insulation |
| Termal İletkenlik | Approximately 0.022-0.030 W/(m·K) for the closed-cell thermal insulation |
| Yüzey bitirme | White low-shedding powder coat with stainless-steel coil and condensate compartment |
| Ortak tip | Gasketed double-skin service doors with flanged supply outlet and trapped condensate-drain connection |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Cleanroom Recirculation Air Unit (RCU) specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca