Unit Udara Peredaran Kembali Bilik Bersih (RCU)
- Return-Air Recirculation
- Optional Cooling Coil
- EC Volume Control
- Integrated Prefilter and HEPA
Pengenalan Produk
The cleanroom recirculation air unit draws room return air through a washable prefilter, passes it across an optional chilled-water coil and drives it through a HEPA or ULPA final filter. Fan, coil, condensate tray and controls are contained in a serviceable vertical cabinet, reducing the duct length required for a local clean zone. Temperature sensors can modulate the coil valve independently of EC fan speed so thermal load and cleanliness airflow are addressed separately. Supply may discharge through a front diffuser or connect to a short ceiling plenum serving adjacent work areas.
Ciri-ciri Utama
The optional chilled-water coil removes local sensible heat without sending all recirculated air back to a remote AHU.
Separate EC fan and valve control allows airflow volume and temperature response to be tuned independently.
A sloped stainless condensate tray provides a defined drainage path beneath the cooling section.
Kebimbangan Produk Pelanggan
High recirculation rates and concentrated equipment heat can overload distant ductwork even when the central make-up air system is correctly sized.
Permohonan yang biasa
Parameter teknikal
Typical enclosure and filtration ranges for a local cleanroom recirculation unit are listed below.
| Bahan Teras | EC centrifugal fan, optional copper-aluminium cooling coil, washable prefilter and micro-glass HEPA or ULPA pack |
|---|---|
| Ketebalan Panel | 550-900 mm cabinet depth |
| Lebar berkesan | 700-1400 mm serviceable cabinet width |
| Panjang maksimum | Up to 2400 mm overall vertical cabinet height |
| Keluli Menghadapi Ketebalan | 1.0-1.5 mm powder-coated steel casing with 1.0-1.5 mm stainless wet-section liner |
| Ketumpatan teras | Approximately 40-60 kg/m³ density for the closed-cell cabinet insulation |
| Kekonduksian Terma | Approximately 0.022-0.030 W/(m·K) for the closed-cell thermal insulation |
| Kemasan permukaan | White low-shedding powder coat with stainless-steel coil and condensate compartment |
| Jenis Bersatu | Gasketed double-skin service doors with flanged supply outlet and trapped condensate-drain connection |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Cleanroom Recirculation Air Unit (RCU) specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)