Unidad de Recirculación de Aire de Sala Limpia (RCU)
- Return-Air Recirculation
- Optional Cooling Coil
- EC Volume Control
- Integrated Prefilter and HEPA
Introducción del producto
The cleanroom recirculation air unit draws room return air through a washable prefilter, passes it across an optional chilled-water coil and drives it through a HEPA or ULPA final filter. Fan, coil, condensate tray and controls are contained in a serviceable vertical cabinet, reducing the duct length required for a local clean zone. Temperature sensors can modulate the coil valve independently of EC fan speed so thermal load and cleanliness airflow are addressed separately. Supply may discharge through a front diffuser or connect to a short ceiling plenum serving adjacent work areas.
Características clave
The optional chilled-water coil removes local sensible heat without sending all recirculated air back to a remote AHU.
Separate EC fan and valve control allows airflow volume and temperature response to be tuned independently.
A sloped stainless condensate tray provides a defined drainage path beneath the cooling section.
Preocupaciones del producto del cliente
High recirculation rates and concentrated equipment heat can overload distant ductwork even when the central make-up air system is correctly sized.
Aplicaciones típicas
Parámetros técnicos
Typical enclosure and filtration ranges for a local cleanroom recirculation unit are listed below.
| Materiales Core | EC centrifugal fan, optional copper-aluminium cooling coil, washable prefilter and micro-glass HEPA or ULPA pack |
|---|---|
| Panel de espesor | 550-900 mm cabinet depth |
| Ancho efectivo | 700-1400 mm serviceable cabinet width |
| Longitud máxima | Up to 2400 mm overall vertical cabinet height |
| Acero frente a espesor | 1.0-1.5 mm powder-coated steel casing with 1.0-1.5 mm stainless wet-section liner |
| Densidad Core | Approximately 40-60 kg/m³ density for the closed-cell cabinet insulation |
| Conductividad térmica | Approximately 0.022-0.030 W/(m·K) for the closed-cell thermal insulation |
| Superficie acabada | White low-shedding powder coat with stainless-steel coil and condensate compartment |
| Tipo conjunto | Gasketed double-skin service doors with flanged supply outlet and trapped condensate-drain connection |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Cleanroom Recirculation Air Unit (RCU) specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita