Inicio / Productos / FFU y equipos de purificación de aire terminal / Cleanroom Recirculation Air Unit (RCU)
FFU y equipos de purificación de aire terminal

Unidad de Recirculación de Aire de Sala Limpia (RCU)

A self-contained return-air module that recirculates, filters and optionally cools local cleanroom air through a controlled EC fan and terminal HEPA or ULPA stage.
  • Return-Air Recirculation
  • Optional Cooling Coil
  • EC Volume Control
  • Integrated Prefilter and HEPA
Solicite un presupuesto. Browse productos

Introducción del producto

The cleanroom recirculation air unit draws room return air through a washable prefilter, passes it across an optional chilled-water coil and drives it through a HEPA or ULPA final filter. Fan, coil, condensate tray and controls are contained in a serviceable vertical cabinet, reducing the duct length required for a local clean zone. Temperature sensors can modulate the coil valve independently of EC fan speed so thermal load and cleanliness airflow are addressed separately. Supply may discharge through a front diffuser or connect to a short ceiling plenum serving adjacent work areas.

Características clave

A return grille and prefilter capture coarse loading before it reaches the cooling coil and final filter.

The optional chilled-water coil removes local sensible heat without sending all recirculated air back to a remote AHU.

Separate EC fan and valve control allows airflow volume and temperature response to be tuned independently.

A sloped stainless condensate tray provides a defined drainage path beneath the cooling section.

Preocupaciones del producto del cliente

High recirculation rates and concentrated equipment heat can overload distant ductwork even when the central make-up air system is correctly sized.

Long return-air paths consume fan energy and leave temperature gradients between process bays.The local RCU recycles room air close to the load and shortens the high-volume airflow path.
Process heat rises while the required clean-air volume remains constant.Independent chilled-water valve modulation adjusts cooling without unnecessarily changing the filtration airflow.
Condensation below a cooling coil creates a hygiene and leakage risk inside the cleanroom envelope.A sloped stainless tray and trapped drain connection collect condensate within the service compartment.
Dust on the coil increases resistance and makes wet-surface cleaning difficult.An accessible upstream prefilter intercepts coarse particles before the coil face.

Aplicaciones típicas

Semiconductor bay recirculationBattery dry-room process zonesSalas de Apoyo FarmacéuticoPrecision metrology laboratoriesLocal high-heat clean equipment areas

Parámetros técnicos

Typical enclosure and filtration ranges for a local cleanroom recirculation unit are listed below.

Materiales CoreEC centrifugal fan, optional copper-aluminium cooling coil, washable prefilter and micro-glass HEPA or ULPA pack
Panel de espesor550-900 mm cabinet depth
Ancho efectivo700-1400 mm serviceable cabinet width
Longitud máximaUp to 2400 mm overall vertical cabinet height
Acero frente a espesor1.0-1.5 mm powder-coated steel casing with 1.0-1.5 mm stainless wet-section liner
Densidad CoreApproximately 40-60 kg/m³ density for the closed-cell cabinet insulation
Conductividad térmicaApproximately 0.022-0.030 W/(m·K) for the closed-cell thermal insulation
Superficie acabadaWhite low-shedding powder coat with stainless-steel coil and condensate compartment
Tipo conjuntoGasketed double-skin service doors with flanged supply outlet and trapped condensate-drain connection
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Cooling-only or fan-and-filter configurationFront discharge or plenum connectionHEPA H14 or ULPA final filterTemperature, pressure and network control package

Planning a Cleanroom Recirculation Air Unit (RCU) specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat