Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Unidad de maquillaje aéreo

A dedicated outdoor-air unit that replaces exhausted process air and maintains the intended cleanroom pressure relationship.
  • Exhaust Air Replacement
  • Pressure Cascade Support
  • Tempered Outdoor Supply
  • Airflow Tracking Control
Solicite un presupuesto. Browse productos

Introducción del producto

The makeup air unit delivers conditioned outside air in proportion to fume-hood, process, canopy or room exhaust. Unlike a general fresh-air unit, its primary control duty is mass-balance: supply airflow must respond predictably as exhaust devices start, stop or modulate. Filters, coils and optional humidity treatment bring the outdoor air to a condition that the room or recirculation system can accept without upsetting temperature and moisture control. A low-leakage casing and fast fan response help prevent door forces and unwanted infiltration.

Características clave

Supply airflow can track a combined exhaust-air signal rather than operate at one fixed ventilation rate.

Tempering coils prevent replacement air from imposing abrupt heating, cooling or moisture loads on the cleanroom.

Fast variable-speed fan control supports stable room pressure during process exhaust transitions.

Separate intake filtration prevents outdoor particles from entering through uncontrolled building leakage paths.

Preocupaciones del producto del cliente

A facility can have sufficient cooling capacity yet still lose pressure control when exhaust and replacement air do not change together.

Starting a process exhaust fan pulls adjacent cleanrooms below their pressure setpoint.The makeup fan follows the combined exhaust airflow signal with a configured offset for pressure cascade.
Untempered winter replacement air causes cold drafts and local condensation.Preheat and final heating stages deliver supply air at a controlled temperature.
Outdoor humidity overwhelms the room AHU during high exhaust operation.Cooling and dehumidification are sized for the full makeup-air latent load.
Unfiltered infiltration enters around doors when replacement air is insufficient.Measured makeup volume enters through staged filters and a defined supply path.

Aplicaciones típicas

Pharmaceutical process exhaust replacementLaboratory fume-hood makeup airClean manufacturing canopy exhaustChemical handling roomsHospital isolation support areas

Parámetros técnicos

Representative makeup-air unit casing and connection ranges are provided below.

Materiales CoreClosed-cell polyurethane or mineral-wool insulation within double-wall casing
Panel de espesor50–60 mm insulated panel
Ancho efectivo800–3000 mm nominal casing width
Longitud máximaUp to 9000 mm with staged filtration and thermal treatment
Acero frente a espesor0.6–1.0 mm sheet steel casing skins
Densidad Core40–43 kg/m³ polyurethane or 80–96 kg/m³ mineral wool
Conductividad térmica0.022–0.040 W/(m·K) according to insulation selection
Superficie acabadaPowder-coated galvanized exterior with galvanized or stainless wet-section interior
Tipo conjuntoThermal-break frame and gasketed block joints with flexible supply-duct connector
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Exhaust-airflow or room-pressure trackingGas, steam, hot-water or electric heatingChilled-water, DX or desiccant dehumidificationOutdoor roof, floor or plant-room arrangement

Planning a Makeup Air Unit specification?