클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 HVAC 및 공기 처리 장비

메이크업 에어 유닛

A dedicated outdoor-air unit that replaces exhausted process air and maintains the intended cleanroom pressure relationship.
  • Exhaust Air Replacement
  • Pressure Cascade Support
  • Tempered Outdoor Supply
  • Airflow Tracking Control
견적 요청 제품 찾아보기

상품 소개

The makeup air unit delivers conditioned outside air in proportion to fume-hood, process, canopy or room exhaust. Unlike a general fresh-air unit, its primary control duty is mass-balance: supply airflow must respond predictably as exhaust devices start, stop or modulate. Filters, coils and optional humidity treatment bring the outdoor air to a condition that the room or recirculation system can accept without upsetting temperature and moisture control. A low-leakage casing and fast fan response help prevent door forces and unwanted infiltration.

주요 기능

Supply airflow can track a combined exhaust-air signal rather than operate at one fixed ventilation rate.

Tempering coils prevent replacement air from imposing abrupt heating, cooling or moisture loads on the cleanroom.

Fast variable-speed fan control supports stable room pressure during process exhaust transitions.

Separate intake filtration prevents outdoor particles from entering through uncontrolled building leakage paths.

고객 제품 관심사

A facility can have sufficient cooling capacity yet still lose pressure control when exhaust and replacement air do not change together.

Starting a process exhaust fan pulls adjacent cleanrooms below their pressure setpoint.The makeup fan follows the combined exhaust airflow signal with a configured offset for pressure cascade.
Untempered winter replacement air causes cold drafts and local condensation.Preheat and final heating stages deliver supply air at a controlled temperature.
Outdoor humidity overwhelms the room AHU during high exhaust operation.Cooling and dehumidification are sized for the full makeup-air latent load.
Unfiltered infiltration enters around doors when replacement air is insufficient.Measured makeup volume enters through staged filters and a defined supply path.

일반적인 응용 프로그램

Pharmaceutical process exhaust replacementLaboratory fume-hood makeup airClean manufacturing canopy exhaustChemical handling roomsHospital isolation support areas

기술 매개변수

Representative makeup-air unit casing and connection ranges are provided below.

핵심 재료Closed-cell polyurethane or mineral-wool insulation within double-wall casing
패널 두께50–60 mm insulated panel
유효 폭800–3000 mm nominal casing width
최대 길이Up to 9000 mm with staged filtration and thermal treatment
강철 면면 두께0.6–1.0 mm sheet steel casing skins
코어 밀도40–43 kg/m³ polyurethane or 80–96 kg/m³ mineral wool
열전도도 (Thermal Conductivity)0.022–0.040 W/(m·K) according to insulation selection
표면 마무리Powder-coated galvanized exterior with galvanized or stainless wet-section interior
접합 유형Thermal-break frame and gasketed block joints with flexible supply-duct connector
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Exhaust-airflow or room-pressure trackingGas, steam, hot-water or electric heatingChilled-water, DX or desiccant dehumidificationOutdoor roof, floor or plant-room arrangement

Planning a Makeup Air Unit specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기