Unit Udara Makeup

A dedicated outdoor-air unit that replaces exhausted process air and maintains the intended cleanroom pressure relationship.
  • Exhaust Air Replacement
  • Pressure Cascade Support
  • Tempered Outdoor Supply
  • Airflow Tracking Control
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The makeup air unit delivers conditioned outside air in proportion to fume-hood, process, canopy or room exhaust. Unlike a general fresh-air unit, its primary control duty is mass-balance: supply airflow must respond predictably as exhaust devices start, stop or modulate. Filters, coils and optional humidity treatment bring the outdoor air to a condition that the room or recirculation system can accept without upsetting temperature and moisture control. A low-leakage casing and fast fan response help prevent door forces and unwanted infiltration.

Ciri-ciri Utama

Supply airflow can track a combined exhaust-air signal rather than operate at one fixed ventilation rate.

Tempering coils prevent replacement air from imposing abrupt heating, cooling or moisture loads on the cleanroom.

Fast variable-speed fan control supports stable room pressure during process exhaust transitions.

Separate intake filtration prevents outdoor particles from entering through uncontrolled building leakage paths.

Kebimbangan Produk Pelanggan

A facility can have sufficient cooling capacity yet still lose pressure control when exhaust and replacement air do not change together.

Starting a process exhaust fan pulls adjacent cleanrooms below their pressure setpoint.The makeup fan follows the combined exhaust airflow signal with a configured offset for pressure cascade.
Untempered winter replacement air causes cold drafts and local condensation.Preheat and final heating stages deliver supply air at a controlled temperature.
Outdoor humidity overwhelms the room AHU during high exhaust operation.Cooling and dehumidification are sized for the full makeup-air latent load.
Unfiltered infiltration enters around doors when replacement air is insufficient.Measured makeup volume enters through staged filters and a defined supply path.

Permohonan yang biasa

Pharmaceutical process exhaust replacementLaboratory fume-hood makeup airClean manufacturing canopy exhaustChemical handling roomsHospital isolation support areas

Parameter teknikal

Representative makeup-air unit casing and connection ranges are provided below.

Bahan TerasClosed-cell polyurethane or mineral-wool insulation within double-wall casing
Ketebalan Panel50–60 mm insulated panel
Lebar berkesan800–3000 mm nominal casing width
Panjang maksimumUp to 9000 mm with staged filtration and thermal treatment
Keluli Menghadapi Ketebalan0.6–1.0 mm sheet steel casing skins
Ketumpatan teras40–43 kg/m³ polyurethane or 80–96 kg/m³ mineral wool
Kekonduksian Terma0.022–0.040 W/(m·K) according to insulation selection
Kemasan permukaanPowder-coated galvanized exterior with galvanized or stainless wet-section interior
Jenis BersatuThermal-break frame and gasketed block joints with flexible supply-duct connector
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Exhaust-airflow or room-pressure trackingGas, steam, hot-water or electric heatingChilled-water, DX or desiccant dehumidificationOutdoor roof, floor or plant-room arrangement