Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
ОВК и оборудование для обработки воздуха в чистых помещениях

Катушка охлаждения с охлажденной водой

A deep-row finned coil that cools and dehumidifies cleanroom air using centrally supplied chilled water and controlled condensate drainage.
  • Sensible and Latent Cooling
  • Hydrophilic Fin Surface
  • Insulated Water Headers
  • Stainless Condensate Drainage
Запрос котировки Просмотреть продукты

Введение продукции

Chilled water circulates through multiple copper-tube rows while warm air crosses blue hydrophilic aluminum fins. When the fin temperature drops below dew point, moisture condenses and drains into a stainless pan beneath the coil. Counterflow circuiting, sufficient face area and controlled fin spacing balance latent performance, water velocity and air pressure drop for cleanroom humidity control.

Основные характеристики

Deep multi-row construction provides both sensible cooling and moisture removal at controlled face velocity.

Hydrophilic fin treatment encourages condensate to form a thin draining film instead of bridging between fins.

Insulated supply and return headers limit external sweating in the AHU casing.

A sloped stainless drain pan captures condensate and exposes the drain outlet for cleaning.

Обеспокоенность клиентов продуктами

Cooling coils must remove moisture without carrying droplets downstream or creating stagnant condensate zones.

High face velocity pulls condensate off the coil into downstream filters.Adequate face area and an optional droplet eliminator keep carryover below the design airflow.
Water retained between fins supports fouling and odor.Hydrophilic coating and a properly pitched coil encourage rapid drainage into the pan.
Uninsulated headers sweat outside the drain-pan footprint.Closed-cell header insulation directs any surface moisture toward contained drainage areas.
Poor circuit balance leaves warm streaks in supply air.Matched circuits and full-width headers distribute chilled water uniformly across the face.

Типичные приложения

Pharmaceutical cleanroom air handlersLow-dew-point make-up air unitsElectronics manufacturing HVACHospital surgical-suite AHUsLaboratory humidity control

Технические параметры

Typical physical construction ranges for a cleanroom chilled-water coil are summarized below.

Основной материалCopper tubes with blue hydrophilic aluminum fins and insulated copper headers
Толщина панели1.5-2.0 mm stainless or galvanized coil casing
эффективная ширина400-3000 mm active fin face width
Максимальная длинаUp to 4200 mm overall coil and drain-pan length
Толщина линий стали1.0-1.5 mm 304 stainless condensate pan
Плотность ядраBase-metal density approximately 2730 kg/m³ for the hydrophilic-coated 3003 aluminum cooling fins
ТеплопроводимостьBase-metal thermal conductivity approximately 193 W/(m·K) for the coated aluminum cooling fins
Поверхностная отделкаBlue hydrophilic-coated aluminum fins with stainless drain pan
Объединенный типBrazed copper circuits in flanged casing with threaded or flanged headers and welded drain pan
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Four to twelve tube rowsHydrophilic, epoxy or corrosion-resistant fin coatingStainless casing and double-slope drain panMoisture eliminator and insulated header enclosure

Planning a Chilled-Water Cooling Coil specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты