冷却水冷却コイル

A deep-row finned coil that cools and dehumidifies cleanroom air using centrally supplied chilled water and controlled condensate drainage.
  • Sensible and Latent Cooling
  • Hydrophilic Fin Surface
  • Insulated Water Headers
  • Stainless Condensate Drainage
見積もりリクエスト 製品案内

商品紹介

Chilled water circulates through multiple copper-tube rows while warm air crosses blue hydrophilic aluminum fins. When the fin temperature drops below dew point, moisture condenses and drains into a stainless pan beneath the coil. Counterflow circuiting, sufficient face area and controlled fin spacing balance latent performance, water velocity and air pressure drop for cleanroom humidity control.

主要な特徴

Deep multi-row construction provides both sensible cooling and moisture removal at controlled face velocity.

Hydrophilic fin treatment encourages condensate to form a thin draining film instead of bridging between fins.

Insulated supply and return headers limit external sweating in the AHU casing.

A sloped stainless drain pan captures condensate and exposes the drain outlet for cleaning.

お客様の製品に関する懸念事項

Cooling coils must remove moisture without carrying droplets downstream or creating stagnant condensate zones.

High face velocity pulls condensate off the coil into downstream filters.Adequate face area and an optional droplet eliminator keep carryover below the design airflow.
Water retained between fins supports fouling and odor.Hydrophilic coating and a properly pitched coil encourage rapid drainage into the pan.
Uninsulated headers sweat outside the drain-pan footprint.Closed-cell header insulation directs any surface moisture toward contained drainage areas.
Poor circuit balance leaves warm streaks in supply air.Matched circuits and full-width headers distribute chilled water uniformly across the face.

典型的な用途

Pharmaceutical cleanroom air handlersLow-dew-point make-up air unitsElectronics manufacturing HVACHospital surgical-suite AHUsLaboratory humidity control

技術的なパラメータ

Typical physical construction ranges for a cleanroom chilled-water coil are summarized below.

コア材料Copper tubes with blue hydrophilic aluminum fins and insulated copper headers
パネルの厚さ1.5-2.0 mm stainless or galvanized coil casing
有効幅400-3000 mm active fin face width
最大長さUp to 4200 mm overall coil and drain-pan length
鋼鉄の厚さを直面する1.0-1.5 mm 304 stainless condensate pan
コア密度Base-metal density approximately 2730 kg/m³ for the hydrophilic-coated 3003 aluminum cooling fins
熱伝導率Base-metal thermal conductivity approximately 193 W/(m·K) for the coated aluminum cooling fins
表面仕上げBlue hydrophilic-coated aluminum fins with stainless drain pan
ジョイントタイプBrazed copper circuits in flanged casing with threaded or flanged headers and welded drain pan
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Four to twelve tube rowsHydrophilic, epoxy or corrosion-resistant fin coatingStainless casing and double-slope drain panMoisture eliminator and insulated header enclosure

Planning a Chilled-Water Cooling Coil specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。