클린룸 HVAC 및 공기 처리 장비
냉각수 냉각 코일 (Chilled Water Cooling Coil)
A deep-row finned coil that cools and dehumidifies cleanroom air using centrally supplied chilled water and controlled condensate drainage.
- Sensible and Latent Cooling
- Hydrophilic Fin Surface
- Insulated Water Headers
- Stainless Condensate Drainage
상품 소개
Chilled water circulates through multiple copper-tube rows while warm air crosses blue hydrophilic aluminum fins. When the fin temperature drops below dew point, moisture condenses and drains into a stainless pan beneath the coil. Counterflow circuiting, sufficient face area and controlled fin spacing balance latent performance, water velocity and air pressure drop for cleanroom humidity control.
주요 기능
Hydrophilic fin treatment encourages condensate to form a thin draining film instead of bridging between fins.
Insulated supply and return headers limit external sweating in the AHU casing.
A sloped stainless drain pan captures condensate and exposes the drain outlet for cleaning.
고객 제품 관심사
Cooling coils must remove moisture without carrying droplets downstream or creating stagnant condensate zones.
High face velocity pulls condensate off the coil into downstream filters.Adequate face area and an optional droplet eliminator keep carryover below the design airflow.
Water retained between fins supports fouling and odor.Hydrophilic coating and a properly pitched coil encourage rapid drainage into the pan.
Uninsulated headers sweat outside the drain-pan footprint.Closed-cell header insulation directs any surface moisture toward contained drainage areas.
Poor circuit balance leaves warm streaks in supply air.Matched circuits and full-width headers distribute chilled water uniformly across the face.
일반적인 응용 프로그램
Pharmaceutical cleanroom air handlersLow-dew-point make-up air unitsElectronics manufacturing HVACHospital surgical-suite AHUsLaboratory humidity control
기술 매개변수
Typical physical construction ranges for a cleanroom chilled-water coil are summarized below.
| 핵심 재료 | Copper tubes with blue hydrophilic aluminum fins and insulated copper headers |
|---|---|
| 패널 두께 | 1.5-2.0 mm stainless or galvanized coil casing |
| 유효 폭 | 400-3000 mm active fin face width |
| 최대 길이 | Up to 4200 mm overall coil and drain-pan length |
| 강철 면면 두께 | 1.0-1.5 mm 304 stainless condensate pan |
| 코어 밀도 | Base-metal density approximately 2730 kg/m³ for the hydrophilic-coated 3003 aluminum cooling fins |
| 열전도도 (Thermal Conductivity) | Base-metal thermal conductivity approximately 193 W/(m·K) for the coated aluminum cooling fins |
| 표면 마무리 | Blue hydrophilic-coated aluminum fins with stainless drain pan |
| 접합 유형 | Brazed copper circuits in flanged casing with threaded or flanged headers and welded drain pan |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Four to twelve tube rowsHydrophilic, epoxy or corrosion-resistant fin coatingStainless casing and double-slope drain panMoisture eliminator and insulated header enclosure
Planning a Chilled-Water Cooling Coil specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

영어
독일어
아랍어
프랑스어
인도네시아어
일본어
한국어현재 Current
말레이어
포르투갈어
러시아어
스페인어
태국어
터키어