/ 제품 / 클린룸 HVAC 및 공기 처리 장비 / Chilled-Water Cooling Coil
클린룸 HVAC 및 공기 처리 장비

냉각수 냉각 코일 (Chilled Water Cooling Coil)

A deep-row finned coil that cools and dehumidifies cleanroom air using centrally supplied chilled water and controlled condensate drainage.
  • Sensible and Latent Cooling
  • Hydrophilic Fin Surface
  • Insulated Water Headers
  • Stainless Condensate Drainage
견적 요청 제품 찾아보기

상품 소개

Chilled water circulates through multiple copper-tube rows while warm air crosses blue hydrophilic aluminum fins. When the fin temperature drops below dew point, moisture condenses and drains into a stainless pan beneath the coil. Counterflow circuiting, sufficient face area and controlled fin spacing balance latent performance, water velocity and air pressure drop for cleanroom humidity control.

주요 기능

Deep multi-row construction provides both sensible cooling and moisture removal at controlled face velocity.

Hydrophilic fin treatment encourages condensate to form a thin draining film instead of bridging between fins.

Insulated supply and return headers limit external sweating in the AHU casing.

A sloped stainless drain pan captures condensate and exposes the drain outlet for cleaning.

고객 제품 관심사

Cooling coils must remove moisture without carrying droplets downstream or creating stagnant condensate zones.

High face velocity pulls condensate off the coil into downstream filters.Adequate face area and an optional droplet eliminator keep carryover below the design airflow.
Water retained between fins supports fouling and odor.Hydrophilic coating and a properly pitched coil encourage rapid drainage into the pan.
Uninsulated headers sweat outside the drain-pan footprint.Closed-cell header insulation directs any surface moisture toward contained drainage areas.
Poor circuit balance leaves warm streaks in supply air.Matched circuits and full-width headers distribute chilled water uniformly across the face.

일반적인 응용 프로그램

Pharmaceutical cleanroom air handlersLow-dew-point make-up air unitsElectronics manufacturing HVACHospital surgical-suite AHUsLaboratory humidity control

기술 매개변수

Typical physical construction ranges for a cleanroom chilled-water coil are summarized below.

핵심 재료Copper tubes with blue hydrophilic aluminum fins and insulated copper headers
패널 두께1.5-2.0 mm stainless or galvanized coil casing
유효 폭400-3000 mm active fin face width
최대 길이Up to 4200 mm overall coil and drain-pan length
강철 면면 두께1.0-1.5 mm 304 stainless condensate pan
코어 밀도Base-metal density approximately 2730 kg/m³ for the hydrophilic-coated 3003 aluminum cooling fins
열전도도 (Thermal Conductivity)Base-metal thermal conductivity approximately 193 W/(m·K) for the coated aluminum cooling fins
표면 마무리Blue hydrophilic-coated aluminum fins with stainless drain pan
접합 유형Brazed copper circuits in flanged casing with threaded or flanged headers and welded drain pan
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Four to twelve tube rowsHydrophilic, epoxy or corrosion-resistant fin coatingStainless casing and double-slope drain panMoisture eliminator and insulated header enclosure

Planning a Chilled-Water Cooling Coil specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat