Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

Brouille de refroidissement à eau refroidie

A deep-row finned coil that cools and dehumidifies cleanroom air using centrally supplied chilled water and controlled condensate drainage.
  • Sensible and Latent Cooling
  • Hydrophilic Fin Surface
  • Insulated Water Headers
  • Stainless Condensate Drainage
Demander un devis. Browse les produits

Introduction de produit

Chilled water circulates through multiple copper-tube rows while warm air crosses blue hydrophilic aluminum fins. When the fin temperature drops below dew point, moisture condenses and drains into a stainless pan beneath the coil. Counterflow circuiting, sufficient face area and controlled fin spacing balance latent performance, water velocity and air pressure drop for cleanroom humidity control.

Key Features

Deep multi-row construction provides both sensible cooling and moisture removal at controlled face velocity.

Hydrophilic fin treatment encourages condensate to form a thin draining film instead of bridging between fins.

Insulated supply and return headers limit external sweating in the AHU casing.

A sloped stainless drain pan captures condensate and exposes the drain outlet for cleaning.

Préoccupations du client produit

Cooling coils must remove moisture without carrying droplets downstream or creating stagnant condensate zones.

High face velocity pulls condensate off the coil into downstream filters.Adequate face area and an optional droplet eliminator keep carryover below the design airflow.
Water retained between fins supports fouling and odor.Hydrophilic coating and a properly pitched coil encourage rapid drainage into the pan.
Uninsulated headers sweat outside the drain-pan footprint.Closed-cell header insulation directs any surface moisture toward contained drainage areas.
Poor circuit balance leaves warm streaks in supply air.Matched circuits and full-width headers distribute chilled water uniformly across the face.

Les applications typiques

Pharmaceutical cleanroom air handlersLow-dew-point make-up air unitsElectronics manufacturing HVACHospital surgical-suite AHUsLaboratory humidity control

Paramètres techniques

Typical physical construction ranges for a cleanroom chilled-water coil are summarized below.

Matériaux de baseCopper tubes with blue hydrophilic aluminum fins and insulated copper headers
Panneau épaisseur1.5-2.0 mm stainless or galvanized coil casing
Largeur effective400-3000 mm active fin face width
Longueur maximaleUp to 4200 mm overall coil and drain-pan length
Acier face épaisseur1.0-1.5 mm 304 stainless condensate pan
Densité CoreBase-metal density approximately 2730 kg/m³ for the hydrophilic-coated 3003 aluminum cooling fins
Conductivité thermiqueBase-metal thermal conductivity approximately 193 W/(m·K) for the coated aluminum cooling fins
surface finieBlue hydrophilic-coated aluminum fins with stainless drain pan
Type jointBrazed copper circuits in flanged casing with threaded or flanged headers and welded drain pan
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Four to twelve tube rowsHydrophilic, epoxy or corrosion-resistant fin coatingStainless casing and double-slope drain panMoisture eliminator and insulated header enclosure

Planning a Chilled-Water Cooling Coil specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact