A sterilizable weighted contact-plate applicator that applies repeatable pressure and timed dwell to flat cleanroom surfaces.
  • Repeatable Contact Pressure
  • Timed Surface Application
  • 55 mm Plate Compatibility
  • Sterilizable Stainless Construction
Solicite um orçamento. Browse produtos

Introdução do produto

The Surface Microbial Sampler is a precision contact weight used with raised-agar contact plates. Its balanced stainless body seats over a standard plate holder and transfers a controlled vertical load to the agar while a small timer defines the dwell period. A spring-guided plunger helps the operator maintain even contact without rocking the plate or concentrating force at one edge. After sampling, the plate is removed and capped for incubation, leaving the applicator available for cleaning or steam sterilization.

Características-chave

A defined weighted load reduces operator-to-operator variation in plate pressure.

The plate-retaining collar centers the contact dish beneath the applicator.

A pull-out timer standardizes the selected contact duration at each location.

Smooth stainless components tolerate repeated cleaning and sterilization.

Preocupações do produto do cliente

Surface recovery varies when operators use different pressure, dwell time or plate angle on the same material.

Hand pressure differs between technicians and sampling rounds.A fixed applicator mass supplies the same nominal load without relying on operator force.
Tilting the plate traps air or contacts only part of the agar dome.A centered collar and guided vertical motion support even face-to-surface contact.
Short or inconsistent dwell time reduces comparability.The integrated timer gives a visible repeatable contact interval.
Complex joints retain disinfectant or surface residue.Removable smooth stainless parts simplify wiping and validated sterilization.

Aplicações típicas

Cleanroom workbench surfacesIsolator and RABS interiorsWalls, floors and equipment panelsCleaning-process verification

Parâmetros técnicos

Typical construction values for a reusable contact-plate surface sampler are listed below.

Material principal304 or 316 stainless weighted body with silicone grip and sealed electronic timer
Painel de espessura55-90 mm weighted body height
Largura efetiva55-70 mm contact-plate seat diameter
Comprimento máximoUp to 180 mm overall height with plunger extended
Aço enfrentando espessura1.5-3.0 mm stainless outer shell and plate collar
Densidade Core7900-8000 kg/m³ for stainless weighted components
Condutividade térmica14-17 W/(m·K) for stainless steel components
Superfície acabadoElectropolished or fine satin stainless steel with blue silicone grip ring
Tipo conjuntoRemovable 55 mm plate-retaining collar with spring-guided plunger and pull-out timer
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

55 mm contact-plate collarAlternative application weightsDigital dwell timerAutoclavable timer-free configuration

Planning a Surface Microbial Sampler specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato