Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Mikrobiologische Umweltüberwachung Produkte

Mikrobielle Oberflächenproben

A sterilizable weighted contact-plate applicator that applies repeatable pressure and timed dwell to flat cleanroom surfaces.
  • Repeatable Contact Pressure
  • Timed Surface Application
  • 55 mm Plate Compatibility
  • Sterilizable Stainless Construction

Produkteinführung

The Surface Microbial Sampler is a precision contact weight used with raised-agar contact plates. Its balanced stainless body seats over a standard plate holder and transfers a controlled vertical load to the agar while a small timer defines the dwell period. A spring-guided plunger helps the operator maintain even contact without rocking the plate or concentrating force at one edge. After sampling, the plate is removed and capped for incubation, leaving the applicator available for cleaning or steam sterilization.

Key Features

A defined weighted load reduces operator-to-operator variation in plate pressure.

The plate-retaining collar centers the contact dish beneath the applicator.

A pull-out timer standardizes the selected contact duration at each location.

Smooth stainless components tolerate repeated cleaning and sterilization.

Kunden Produktbedenken

Surface recovery varies when operators use different pressure, dwell time or plate angle on the same material.

Hand pressure differs between technicians and sampling rounds.A fixed applicator mass supplies the same nominal load without relying on operator force.
Tilting the plate traps air or contacts only part of the agar dome.A centered collar and guided vertical motion support even face-to-surface contact.
Short or inconsistent dwell time reduces comparability.The integrated timer gives a visible repeatable contact interval.
Complex joints retain disinfectant or surface residue.Removable smooth stainless parts simplify wiping and validated sterilization.

Typische Anwendungen

Cleanroom workbench surfacesIsolator and RABS interiorsWalls, floors and equipment panelsCleaning-process verification

Technische Parameter

Typical construction values for a reusable contact-plate surface sampler are listed below.

Core Material304 or 316 stainless weighted body with silicone grip and sealed electronic timer
Panel Dicke55-90 mm weighted body height
Effektive Breite55-70 mm contact-plate seat diameter
Maximale LängeUp to 180 mm overall height with plunger extended
Stahl facing Dicke1.5-3.0 mm stainless outer shell and plate collar
Kerndichte7900-8000 kg/m³ for stainless weighted components
Thermische Leitfähigkeit14-17 W/(m·K) for stainless steel components
Oberfläche FinishElectropolished or fine satin stainless steel with blue silicone grip ring
Gemeinsamer TypRemovable 55 mm plate-retaining collar with spring-guided plunger and pull-out timer
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

55 mm contact-plate collarAlternative application weightsDigital dwell timerAutoclavable timer-free configuration

Planning a Surface Microbial Sampler specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt