A fixed-location optical particle sensor that continuously counts airborne particles at a cleanroom sample point and sends channel data to the monitoring system.
  • Continuous Particle Counting
  • Multiple Size Channels
  • Remote Vacuum Sampling
  • Digital Monitoring Output
Solicite um orçamento. Browse produtos

Introdução do produto

The remote airborne particle sensor draws a controlled sample through an isokinetic probe and laser scattering chamber. Individual particles interrupt the laser beam and are classified by signal amplitude into configured size channels. The compact stainless or coated housing mounts near the sample point while vacuum, power and communication remain accessible from the service side. Continuous counts and sensor-health status are transferred to the environmental monitoring platform for real-time display, alarming and historical review.

Características-chave

Laser light scattering detects and sorts nonviable airborne particles by optical size.

A remote isokinetic probe presents the inlet correctly to the cleanroom airflow direction.

External vacuum or integrated pumping options support continuous fixed-point sampling.

Digital output carries particle channels, flow status and instrument alarms together.

Preocupações do produto do cliente

Continuous particle monitoring depends on representative sampling, stable flow and prompt detection of blocked tubing or vacuum loss.

A poorly oriented inlet under-samples larger particles moving with the room airflow.An isokinetic probe aligns the sample opening with the local cleanroom flow direction.
Long tubing allows particle loss before the sample reaches the sensor.Mounting the sensor close to the probe shortens the particle path and reduces deposition.
Vacuum loss produces zero counts that look like clean air.Flow and vacuum diagnostics create a separate instrument alarm rather than reporting a false normal result.
Service activity exposes the room side to open wiring and tubing.Service-side connections and a clean stainless or coated enclosure preserve the cleanroom face.

Aplicações típicas

Aseptic filling zonesPharmaceutical cleanroomsSemiconductor mini-environmentsContinuous critical-point monitoring

Parâmetros técnicos

Typical construction values for a fixed remote cleanroom particle sensor are listed below.

Material principalOptical glass laser chamber in anodized aluminum frame with stainless steel or coated enclosure
Painel de espessura80-140 mm sensor depth
Largura efetiva100-180 mm housing width
Comprimento máximoUp to 300 mm enclosure length
Aço enfrentando espessura0.8-1.2 mm stainless or coated steel housing
Densidade Core2650-8030 kg/m³ across aluminum frame and stainless enclosure parts
Condutividade térmica14-220 W/(m·K) across stainless and aluminum structural components
Superfície acabadoBrushed stainless steel or smooth white coated housing with blue status LED
Tipo conjuntoIsokinetic sample inlet, barbed vacuum outlet and sealed power-data connectors
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Two or multiple particle channelsExternal or integrated vacuumStainless isokinetic probeEthernet or serial communication

Planning a Remote Airborne Particle Sensor specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato