موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

استشعار الجسيمات المحمولة جواً عن بعد

A fixed-location optical particle sensor that continuously counts airborne particles at a cleanroom sample point and sends channel data to the monitoring system.
  • Continuous Particle Counting
  • Multiple Size Channels
  • Remote Vacuum Sampling
  • Digital Monitoring Output
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The remote airborne particle sensor draws a controlled sample through an isokinetic probe and laser scattering chamber. Individual particles interrupt the laser beam and are classified by signal amplitude into configured size channels. The compact stainless or coated housing mounts near the sample point while vacuum, power and communication remain accessible from the service side. Continuous counts and sensor-health status are transferred to the environmental monitoring platform for real-time display, alarming and historical review.

الخصائص الرئيسية

Laser light scattering detects and sorts nonviable airborne particles by optical size.

A remote isokinetic probe presents the inlet correctly to the cleanroom airflow direction.

External vacuum or integrated pumping options support continuous fixed-point sampling.

Digital output carries particle channels, flow status and instrument alarms together.

مخاوف المنتج للعملاء

Continuous particle monitoring depends on representative sampling, stable flow and prompt detection of blocked tubing or vacuum loss.

A poorly oriented inlet under-samples larger particles moving with the room airflow.An isokinetic probe aligns the sample opening with the local cleanroom flow direction.
Long tubing allows particle loss before the sample reaches the sensor.Mounting the sensor close to the probe shortens the particle path and reduces deposition.
Vacuum loss produces zero counts that look like clean air.Flow and vacuum diagnostics create a separate instrument alarm rather than reporting a false normal result.
Service activity exposes the room side to open wiring and tubing.Service-side connections and a clean stainless or coated enclosure preserve the cleanroom face.

تطبيقات نموذجية

Aseptic filling zonesPharmaceutical cleanroomsSemiconductor mini-environmentsContinuous critical-point monitoring

المعلمات الفنية

Typical construction values for a fixed remote cleanroom particle sensor are listed below.

المواد الأساسيةOptical glass laser chamber in anodized aluminum frame with stainless steel or coated enclosure
سمك اللوحة80-140 mm sensor depth
العرض الفعال100-180 mm housing width
الحد الأقصى الطولUp to 300 mm enclosure length
الصلب يواجه سمك0.8-1.2 mm stainless or coated steel housing
الكثافة الأساسية2650-8030 kg/m³ across aluminum frame and stainless enclosure parts
الموصلية الحرارية14-220 W/(m·K) across stainless and aluminum structural components
إنهاء السطحBrushed stainless steel or smooth white coated housing with blue status LED
نوع المشتركIsokinetic sample inlet, barbed vacuum outlet and sealed power-data connectors
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Two or multiple particle channelsExternal or integrated vacuumStainless isokinetic probeEthernet or serial communication

Planning a Remote Airborne Particle Sensor specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.