Sala de Operações Laminar Flow Ceiling
- Six-Module HEPA Array
- Unidirectional Downflow Face
- Room-Side Filter Service
- Integrated Linear Lighting
Introdução do produto
The operating room laminar flow ceiling combines a shallow sealed supply plenum, six terminal HEPA modules and a planar perforated diffuser face in one suspended canopy. Conditioned air enters through the centered top collar, equalizes inside the pressure chamber and passes vertically through the filter array. Powder-coated steel casing, anodized aluminum filter rails, gasketed room-side retainers and two recessed light strips form a coordinated ceiling terminal with accessible service points and cleanable exposed surfaces.
Características-chave
Perforated diffuser panels add resistance after the filters to reduce local jets and improve distribution across the canopy face.
Room-side latches and continuous gaskets allow individual filter access while maintaining a defined sealing interface.
Two recessed linear luminaires sit outside the active filter grid so task lighting does not divide the central airflow area.
Preocupações do produto do cliente
A surgical canopy must deliver a broad, stable filtered-air zone while preserving service access and coordinating ceiling-mounted lighting and ventilation interfaces.
Aplicações típicas
Parâmetros técnicos
Typical configurable construction values for a rectangular operating-room laminar airflow ceiling are listed below.
| Material principal | Epoxy powder-coated galvanized steel plenum with anodized EN AW-6063 aluminum frames, H14 HEPA modules and perforated diffusers |
|---|---|
| Painel de espessura | 400-450 mm overall plenum depth |
| Largura efetiva | 1880-2480 mm nominal diffuser width |
| Comprimento máximo | Up to 3080 mm standard canopy length |
| Aço enfrentando espessura | 1.0-1.2 mm powder-coated galvanized or optional stainless plenum sheet |
| Densidade Core | 2700 kg/m³ for anodized EN AW-6063 aluminum frame components |
| Condutividade térmica | 200-220 W/(m·K) for EN AW-6063 aluminum framing at room temperature |
| Superfície acabado | RAL 9010 epoxy powder-coated housing with satin anodized aluminum rails and white perforated diffuser faces |
| Tipo conjunto | Gasketed room-side filter locking frames within a modular perimeter, sealed top plenum and flanged rectangular inlet |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Operating Room Laminar Flow Ceiling specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã