Sala de operaciones Laminar Flow Ceiling
- Six-Module HEPA Array
- Unidirectional Downflow Face
- Room-Side Filter Service
- Integrated Linear Lighting
Introducción del producto
The operating room laminar flow ceiling combines a shallow sealed supply plenum, six terminal HEPA modules and a planar perforated diffuser face in one suspended canopy. Conditioned air enters through the centered top collar, equalizes inside the pressure chamber and passes vertically through the filter array. Powder-coated steel casing, anodized aluminum filter rails, gasketed room-side retainers and two recessed light strips form a coordinated ceiling terminal with accessible service points and cleanable exposed surfaces.
Características clave
Perforated diffuser panels add resistance after the filters to reduce local jets and improve distribution across the canopy face.
Room-side latches and continuous gaskets allow individual filter access while maintaining a defined sealing interface.
Two recessed linear luminaires sit outside the active filter grid so task lighting does not divide the central airflow area.
Preocupaciones del producto del cliente
A surgical canopy must deliver a broad, stable filtered-air zone while preserving service access and coordinating ceiling-mounted lighting and ventilation interfaces.
Aplicaciones típicas
Parámetros técnicos
Typical configurable construction values for a rectangular operating-room laminar airflow ceiling are listed below.
| Materiales Core | Epoxy powder-coated galvanized steel plenum with anodized EN AW-6063 aluminum frames, H14 HEPA modules and perforated diffusers |
|---|---|
| Panel de espesor | 400-450 mm overall plenum depth |
| Ancho efectivo | 1880-2480 mm nominal diffuser width |
| Longitud máxima | Up to 3080 mm standard canopy length |
| Acero frente a espesor | 1.0-1.2 mm powder-coated galvanized or optional stainless plenum sheet |
| Densidad Core | 2700 kg/m³ for anodized EN AW-6063 aluminum frame components |
| Conductividad térmica | 200-220 W/(m·K) for EN AW-6063 aluminum framing at room temperature |
| Superficie acabada | RAL 9010 epoxy powder-coated housing with satin anodized aluminum rails and white perforated diffuser faces |
| Tipo conjunto | Gasketed room-side filter locking frames within a modular perimeter, sealed top plenum and flanged rectangular inlet |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Operating Room Laminar Flow Ceiling specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita