Salle d'opération Laminar Flow Plafond
- Six-Module HEPA Array
- Unidirectional Downflow Face
- Room-Side Filter Service
- Integrated Linear Lighting
Introduction de produit
The operating room laminar flow ceiling combines a shallow sealed supply plenum, six terminal HEPA modules and a planar perforated diffuser face in one suspended canopy. Conditioned air enters through the centered top collar, equalizes inside the pressure chamber and passes vertically through the filter array. Powder-coated steel casing, anodized aluminum filter rails, gasketed room-side retainers and two recessed light strips form a coordinated ceiling terminal with accessible service points and cleanable exposed surfaces.
Key Features
Perforated diffuser panels add resistance after the filters to reduce local jets and improve distribution across the canopy face.
Room-side latches and continuous gaskets allow individual filter access while maintaining a defined sealing interface.
Two recessed linear luminaires sit outside the active filter grid so task lighting does not divide the central airflow area.
Préoccupations du client produit
A surgical canopy must deliver a broad, stable filtered-air zone while preserving service access and coordinating ceiling-mounted lighting and ventilation interfaces.
Les applications typiques
Paramètres techniques
Typical configurable construction values for a rectangular operating-room laminar airflow ceiling are listed below.
| Matériaux de base | Epoxy powder-coated galvanized steel plenum with anodized EN AW-6063 aluminum frames, H14 HEPA modules and perforated diffusers |
|---|---|
| Panneau épaisseur | 400-450 mm overall plenum depth |
| Largeur effective | 1880-2480 mm nominal diffuser width |
| Longueur maximale | Up to 3080 mm standard canopy length |
| Acier face épaisseur | 1.0-1.2 mm powder-coated galvanized or optional stainless plenum sheet |
| Densité Core | 2700 kg/m³ for anodized EN AW-6063 aluminum frame components |
| Conductivité thermique | 200-220 W/(m·K) for EN AW-6063 aluminum framing at room temperature |
| surface finie | RAL 9010 epoxy powder-coated housing with satin anodized aluminum rails and white perforated diffuser faces |
| Type joint | Gasketed room-side filter locking frames within a modular perimeter, sealed top plenum and flanged rectangular inlet |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Operating Room Laminar Flow Ceiling specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien