Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Filtros de ar e filtragem química / Low-Resistance HEPA Filter
Filtros de ar e filtragem química

Z Filtro HEPA de baixa resistência

An optimized mini-pleat HEPA panel that combines fine glass-microfibre media with uniform pleat channels to reduce fan resistance at cleanroom operating airflow.
  • Optimized Pleat Geometry
  • Reduced Fan Resistance
  • Uniform Air Distribution
  • Slim Aluminium Frame
Solicite um orçamento. Browse produtos

Introdução do produto

The low-resistance HEPA filter is built around a closely controlled mini-pleat pack with precisely spaced hot-melt beads. Greater effective media area and uniform channel depth reduce local velocity peaks that add pressure loss. The pack is sealed into an anodized-aluminium frame with polyurethane and protected by a lightweight expanded-metal faceguard. Gasket, gel and knife-edge versions fit common terminal housings, fan filter units and low-energy air-handling systems where stable HEPA performance must be achieved with a limited fan-pressure budget.

Características-chave

Optimized pleat height and spacing increase usable media area without restricting the discharge face.

Even hot-melt separators reduce turbulent flow and prevent pleat crowding at operating pressure.

A slim anodized-aluminium frame limits weight while maintaining cleanroom-compatible surfaces.

Multiple perimeter-seal formats allow the same low-resistance media concept to fit ceiling or AHU housings.

Preocupações do produto do cliente

A cleanroom may meet particle targets yet consume unnecessary energy if the final filter imposes avoidable resistance throughout its service life.

Existing FFU motors run near maximum speed to overcome the terminal filter.The expanded mini-pleat area lowers media velocity and preserves more usable fan-pressure reserve.
Uneven pleat spacing produces early loading in isolated sections of the filter.Consistent separator placement distributes airflow and particulate capture across the whole face.
A bulky deep filter will not fit the available ceiling plenum.The shallow aluminium-frame panel provides HEPA filtration in common 69–90 mm terminal depths.
Reducing pressure drop must not create a fragile media pack.Faceguards, continuous edge potting and controlled pleat geometry support the pack during handling and operation.

Aplicações típicas

Energy-efficient fan filter unitsLow-pressure cleanroom ceilingsSemiconductor process baysPharmaceutical filling suitesClean laboratory supply terminals

Parâmetros técnicos

Typical low-resistance mini-pleat HEPA panel ranges are listed below.

Material principalHigh-area glass-microfibre HEPA media with thermoplastic mini-pleat separators
Painel de espessura69–90 mm aluminium-frame depth
Largura efetiva305 - 610 mm Largura nominal da face
Comprimento máximoAté 1220 mm de comprimento nominal do rosto
Aço enfrentando espessura0.4–0.6 mm galvanized or powder-coated expanded-steel faceguard
Densidade CoreApproximately 30–45 kg/m³ equivalent mini-pleat media density
Condutividade térmicaApproximately 0.035–0.043 W/(m·K) for the dry glass-microfibre pack
Superfície acabadoNatural anodized-aluminium frame with clean white or galvanized faceguards
Tipo conjuntoEPDM gasket, polyurethane gel channel or extruded knife-edge frame
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

H13 or H14 efficiency69 mm or 90 mm frame depthDry gasket or fluid-gel sealPowder-coated or stainless-steel faceguard

Planning a Low-Resistance HEPA Filter specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato