クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / エアフィルターと化学ろ過 / Low-Resistance HEPA Filter
エアフィルターと化学ろ過

低抵抗 HEPA フィルタ

An optimized mini-pleat HEPA panel that combines fine glass-microfibre media with uniform pleat channels to reduce fan resistance at cleanroom operating airflow.
  • Optimized Pleat Geometry
  • Reduced Fan Resistance
  • Uniform Air Distribution
  • Slim Aluminium Frame
見積もりリクエスト 製品案内

商品紹介

The low-resistance HEPA filter is built around a closely controlled mini-pleat pack with precisely spaced hot-melt beads. Greater effective media area and uniform channel depth reduce local velocity peaks that add pressure loss. The pack is sealed into an anodized-aluminium frame with polyurethane and protected by a lightweight expanded-metal faceguard. Gasket, gel and knife-edge versions fit common terminal housings, fan filter units and low-energy air-handling systems where stable HEPA performance must be achieved with a limited fan-pressure budget.

主要な特徴

Optimized pleat height and spacing increase usable media area without restricting the discharge face.

Even hot-melt separators reduce turbulent flow and prevent pleat crowding at operating pressure.

A slim anodized-aluminium frame limits weight while maintaining cleanroom-compatible surfaces.

Multiple perimeter-seal formats allow the same low-resistance media concept to fit ceiling or AHU housings.

お客様の製品に関する懸念事項

A cleanroom may meet particle targets yet consume unnecessary energy if the final filter imposes avoidable resistance throughout its service life.

Existing FFU motors run near maximum speed to overcome the terminal filter.The expanded mini-pleat area lowers media velocity and preserves more usable fan-pressure reserve.
Uneven pleat spacing produces early loading in isolated sections of the filter.Consistent separator placement distributes airflow and particulate capture across the whole face.
A bulky deep filter will not fit the available ceiling plenum.The shallow aluminium-frame panel provides HEPA filtration in common 69–90 mm terminal depths.
Reducing pressure drop must not create a fragile media pack.Faceguards, continuous edge potting and controlled pleat geometry support the pack during handling and operation.

典型的な用途

Energy-efficient fan filter unitsLow-pressure cleanroom ceilingsSemiconductor process baysPharmaceutical filling suitesClean laboratory supply terminals

技術的なパラメータ

Typical low-resistance mini-pleat HEPA panel ranges are listed below.

コア材料High-area glass-microfibre HEPA media with thermoplastic mini-pleat separators
パネルの厚さ69–90 mm aluminium-frame depth
有効幅305 — 610 mm 公称面幅
最大長さUp to 1220 mm nominal face length
鋼鉄の厚さを直面する0.4–0.6 mm galvanized or powder-coated expanded-steel faceguard
コア密度Approximately 30–45 kg/m³ equivalent mini-pleat media density
熱伝導率Approximately 0.035–0.043 W/(m·K) for the dry glass-microfibre pack
表面仕上げNatural anodized-aluminium frame with clean white or galvanized faceguards
ジョイントタイプEPDM gasket, polyurethane gel channel or extruded knife-edge frame
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

H13 or H14 efficiency69 mm or 90 mm frame depthDry gasket or fluid-gel sealPowder-coated or stainless-steel faceguard

Planning a Low-Resistance HEPA Filter specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ