Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Fluxo laminar e equipamentos de contenção / Ceiling-Suspended Laminar Flow Hood
Fluxo laminar e equipamentos de contenção

Capuz de fluxo laminar suspenso no teto

An overhead HEPA-filtered hood suspended above process equipment to create a defined downward clean-air zone without floor-mounted supports.
  • Floor-Free Suspension
  • Overhead HEPA Downflow
  • Adjustable Hanging Height
  • Optional Flexible Curtains
Solicite um orçamento. Browse produtos

Introdução do produto

The suspended hood mounts from the building structure above a filling point, inspection table or compact process machine. A rigid supply plenum distributes HEPA-filtered air through the lower diffuser, while adjustable threaded hangers set the operating height and maintain level. Optional clear curtains extend the protected zone without permanent walls. Structural loads, electrical routing and service clearance are coordinated above the ceiling, leaving the floor around the process accessible.

Características-chave

Four-point suspension keeps posts and bases away from the process floor.

A pressure-equalizing plenum supplies the complete lower diffuser evenly.

Height-adjustable hangers accommodate equipment and ceiling variations.

Flexible clear curtains can limit cross-drafts around selected sides.

A hinged or lift-down filter panel allows service from the clean side when required.

Preocupações do produto do cliente

An overhead hood must deliver an even clean-air footprint while remaining structurally secure and serviceable above operating equipment.

Floor legs obstruct carts and cleaning around the process.Ceiling suspension leaves the floor perimeter open.
An uneven hanging frame tilts the airflow diffuser.Individually adjustable hangers allow the plenum to be leveled after installation.
Room cross-drafts shorten the protected downflow zone.Optional clear curtains extend from the hood edge around the critical process area.
Filter replacement conflicts with equipment below.A selected top-service or clean-side lift-down arrangement matches the available access route.

Aplicações típicas

Open-vial handling zonesClean filling-point coveragePrecision assembly islandsInspection tables beneath high ceilings

Parâmetros técnicos

Typical configurable construction ranges for a ceiling-suspended laminar flow hood are listed below.

Material principalAnodized aluminum plenum frame with powder-coated steel skins and aluminum honeycomb diffuser panels
Painel de espessura40-80 mm plenum and diffuser assembly
Largura efetiva1200-3000 mm protected airflow width
Comprimento máximoUp to 4000 mm protected airflow length
Aço enfrentando espessura0.8-1.2 mm powder-coated steel plenum skins
Densidade Core30-50 kg/m³ aluminum honeycomb diffuser core
Condutividade térmica1.5-2.5 W/(m·K) across the aluminum honeycomb diffuser assembly
Superfície acabadoWhite powder-coated plenum with natural anodized frame and clear PVC curtain option
Tipo conjuntoBolted suspension frame with gasketed filter modules and sealed plenum flanges
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Top-service or room-side filter accessFlexible clear curtainsIntegrated LED lightingRemote or plenum-mounted EC fans

Planning a Ceiling-Suspended Laminar Flow Hood specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato