An overhead HEPA-filtered hood suspended above process equipment to create a defined downward clean-air zone without floor-mounted supports.
  • Floor-Free Suspension
  • Overhead HEPA Downflow
  • Adjustable Hanging Height
  • Optional Flexible Curtains
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The suspended hood mounts from the building structure above a filling point, inspection table or compact process machine. A rigid supply plenum distributes HEPA-filtered air through the lower diffuser, while adjustable threaded hangers set the operating height and maintain level. Optional clear curtains extend the protected zone without permanent walls. Structural loads, electrical routing and service clearance are coordinated above the ceiling, leaving the floor around the process accessible.

Ciri-ciri Utama

Four-point suspension keeps posts and bases away from the process floor.

A pressure-equalizing plenum supplies the complete lower diffuser evenly.

Height-adjustable hangers accommodate equipment and ceiling variations.

Flexible clear curtains can limit cross-drafts around selected sides.

A hinged or lift-down filter panel allows service from the clean side when required.

Kebimbangan Produk Pelanggan

An overhead hood must deliver an even clean-air footprint while remaining structurally secure and serviceable above operating equipment.

Floor legs obstruct carts and cleaning around the process.Ceiling suspension leaves the floor perimeter open.
An uneven hanging frame tilts the airflow diffuser.Individually adjustable hangers allow the plenum to be leveled after installation.
Room cross-drafts shorten the protected downflow zone.Optional clear curtains extend from the hood edge around the critical process area.
Filter replacement conflicts with equipment below.A selected top-service or clean-side lift-down arrangement matches the available access route.

Permohonan yang biasa

Open-vial handling zonesClean filling-point coveragePrecision assembly islandsInspection tables beneath high ceilings

Parameter teknikal

Typical configurable construction ranges for a ceiling-suspended laminar flow hood are listed below.

Bahan TerasAnodized aluminum plenum frame with powder-coated steel skins and aluminum honeycomb diffuser panels
Ketebalan Panel40-80 mm plenum and diffuser assembly
Lebar berkesan1200-3000 mm protected airflow width
Panjang maksimumUp to 4000 mm protected airflow length
Keluli Menghadapi Ketebalan0.8-1.2 mm powder-coated steel plenum skins
Ketumpatan teras30-50 kg/m³ aluminum honeycomb diffuser core
Kekonduksian Terma1.5-2.5 W/(m·K) across the aluminum honeycomb diffuser assembly
Kemasan permukaanWhite powder-coated plenum with natural anodized frame and clear PVC curtain option
Jenis BersatuBolted suspension frame with gasketed filter modules and sealed plenum flanges
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Top-service or room-side filter accessFlexible clear curtainsIntegrated LED lightingRemote or plenum-mounted EC fans