Cleanroom Doors, Windows and Interlock Systems
Interlocked Cleanroom Door
A sealed hygienic swing door prepared with monitored locking and position sensing so only one connected airlock door opens at a time.
- Personnel Airlock Entrance
- 40-55 mm Hygienic Leaf
- Metal or GRP Finish
- Controller-Ready Door Package
Product Introduction
The Interlocked Cleanroom Door combines a flush hygienic leaf and sealed frame with concealed door-position sensing, monitored electric locking and a controller-ready cable path. When paired with another door, the logic prevents simultaneous opening and preserves the pressure buffer inside the airlock. Local indicators and emergency release functions provide clear operating feedback without cluttering the clean-side surface.
Key Features
Monitored electromagnetic or bolt locking confirms whether the leaf is secured.
Flush cable routing keeps electrical connections protected inside the frame.
Local status indicator communicates when the opposite door is occupied or released.
Continuous gaskets support pressure separation after the control sequence completes.
Customer Product Concerns
Two airlock doors opened together collapse the intended pressure buffer.Interlock logic holds the second monitored lock until the first door is securely closed.
Operators cannot tell why a door remains locked.Local red-green indicators communicate door availability and cycle status.
Surface-mounted wiring creates cleaning obstacles around the frame.Prepared concealed cable channels carry sensor, lock and indicator wiring inside the assembly.
A misaligned leaf sends unreliable status signals to the controller.Adjustable concealed sensors and controlled closing bring the door consistently to its monitored position.
Typical Applications
Personnel cleanroom airlocksMaterial transfer lobbiesSterile manufacturing entrancesContainment laboratory vestibulesPressure-cascade gowning rooms
Technical Parameters
| Core Material | Aluminum honeycomb or rigid polyurethane foam within a sealed metal or hygienic composite leaf |
|---|---|
| Panel Thickness | 40–55 mm |
| Effective Width | 800–1200 mm clear opening per leaf |
| Maximum Length | Up to 2600 mm leaf height |
| Steel Facing Thickness | 0.8–1.2 mm coated or stainless-steel facing where selected |
| Core Density | 40–60 kg/m³ for polyurethane-core construction |
| Thermal Conductivity | 0.024–0.040 W/(m·K), depending on core construction |
| Surface Finish | Powder-coated steel, brushed 304 stainless steel or seamless hygienic GRP |
| Joint Type | Gasketed swing leaf with monitored lock, concealed position sensor and interlock-controller connection |
| Customization | Available based on the intended application and operating environment. |
Available Options
Two-door or multi-door controller interfaceElectromagnetic or electric-bolt lockTouchless request-to-open switchEmergency release and battery backup
Planning a Interlocked Cleanroom Door specification?
Send us your dimensions, installation conditions, performance targets and required surface finish.