Lumière germicide UV

A fixed UV-C surface-treatment luminaire with a polished reflector and protected control circuit for scheduled unoccupied-room operation.
  • Short-Wave UV-C Source
  • Polished Directional Reflector
  • Interlock-Ready Circuit
  • Visible Operating Indicator
Demander un devis. Browse les produits

Introduction de produit

The fixed germicidal luminaire mounts to a wall or ceiling and directs UV-C energy toward the defined treatment surface. Low-pressure UV lamps or suitable emitters sit within a corrosion-resistant reflector, while the ballast and terminals are enclosed behind a separate cover. The control connection can accept door, occupancy or remote timer signals so exposure is limited to the intended operating sequence.

Key Features

A polished aluminum reflector directs output toward the selected treatment zone.

The electrical chamber shields the ballast and terminals from the exposed lamp area.

A remote-enable input supports door, occupancy and timer control architecture.

A distinct status indicator makes an active treatment cycle visible.

Tool-retained lamp guards reduce accidental contact during servicing.

Préoccupations du client produit

UV-C is useful only when dose, line of sight, material compatibility and safeguards are considered together for the specific installation.

Shadowed surfaces receive much less direct irradiation.Reflector orientation and multiple mounting positions are planned around the actual geometry.
A conventional light switch can energize the fixture while people are present.Dedicated interlock and remote-enable inputs separate treatment control from room lighting.
UV exposure degrades unprotected polymers and seals.UV-resistant adjacent materials and controlled cycle duration reduce unnecessary exposure.
Operators cannot distinguish standby from active treatment.A separate visible warning indicator confirms when the UV-C circuit is energized.

Les applications typiques

Unoccupied cleanroom surface treatmentPass-through interior treatmentAir-handling irradiation sectionsLaboratory room cycles

Paramètres techniques

Typical configurable construction ranges for a fixed UV-C germicidal luminaire are listed below.

Matériaux de baseStainless or coated-steel electrical body with polished aluminum reflector, UV-C lamp and protected ballast
Panneau épaisseur70-160 mm complete reflector and housing depth
Largeur effective120-350 mm reflector width
Longueur maximaleUp to 1500 mm complete luminaire length
Acier face épaisseur0.8-1.2 mm stainless or coated-steel electrical enclosure
Densité CoreApproximately 2700 kg/m³ for the aluminum reflector
Conductivité thermique160-205 W/(m·K) for the aluminum reflector body
surface finieBright polished aluminum reflector with white or brushed stainless electrical housing
Type jointTool-retained lamp guards with gasketed electrical compartment and hardwired interlock terminals
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Open direct or louver-shielded reflectorWall, ceiling or duct mountingRemote timer and door interlock inputSingle- or twin-lamp body