Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Reinraum Beleuchtung und elektrische Ausrüstung

UV germicides Licht

A fixed UV-C surface-treatment luminaire with a polished reflector and protected control circuit for scheduled unoccupied-room operation.
  • Short-Wave UV-C Source
  • Polished Directional Reflector
  • Interlock-Ready Circuit
  • Visible Operating Indicator

Produkteinführung

The fixed germicidal luminaire mounts to a wall or ceiling and directs UV-C energy toward the defined treatment surface. Low-pressure UV lamps or suitable emitters sit within a corrosion-resistant reflector, while the ballast and terminals are enclosed behind a separate cover. The control connection can accept door, occupancy or remote timer signals so exposure is limited to the intended operating sequence.

Key Features

A polished aluminum reflector directs output toward the selected treatment zone.

The electrical chamber shields the ballast and terminals from the exposed lamp area.

A remote-enable input supports door, occupancy and timer control architecture.

A distinct status indicator makes an active treatment cycle visible.

Tool-retained lamp guards reduce accidental contact during servicing.

Kunden Produktbedenken

UV-C is useful only when dose, line of sight, material compatibility and safeguards are considered together for the specific installation.

Shadowed surfaces receive much less direct irradiation.Reflector orientation and multiple mounting positions are planned around the actual geometry.
A conventional light switch can energize the fixture while people are present.Dedicated interlock and remote-enable inputs separate treatment control from room lighting.
UV exposure degrades unprotected polymers and seals.UV-resistant adjacent materials and controlled cycle duration reduce unnecessary exposure.
Operators cannot distinguish standby from active treatment.A separate visible warning indicator confirms when the UV-C circuit is energized.

Typische Anwendungen

Unoccupied cleanroom surface treatmentPass-through interior treatmentAir-handling irradiation sectionsLaboratory room cycles

Technische Parameter

Typical configurable construction ranges for a fixed UV-C germicidal luminaire are listed below.

Core MaterialStainless or coated-steel electrical body with polished aluminum reflector, UV-C lamp and protected ballast
Panel Dicke70-160 mm complete reflector and housing depth
Effektive Breite120-350 mm reflector width
Maximale LängeUp to 1500 mm complete luminaire length
Stahl facing Dicke0.8-1.2 mm stainless or coated-steel electrical enclosure
KerndichteApproximately 2700 kg/m³ for the aluminum reflector
Thermische Leitfähigkeit160-205 W/(m·K) for the aluminum reflector body
Oberfläche FinishBright polished aluminum reflector with white or brushed stainless electrical housing
Gemeinsamer TypTool-retained lamp guards with gasketed electrical compartment and hardwired interlock terminals
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Open direct or louver-shielded reflectorWall, ceiling or duct mountingRemote timer and door interlock inputSingle- or twin-lamp body

Planning a UV Germicidal Light specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt