مقدمة المنتج

The horizontal air handling unit places dampers, filters, coils and fans in a straight line on a rigid floor base. The layout offers generous face area for filters and coils, helping reduce pressure loss and water carryover. Service doors can reach each section from one side, and the unit height can be kept below roof beams or service distribution. Draw-through and blow-through arrangements are available to suit coil control, fan heat and discharge requirements.

الخصائص الرئيسية

A linear airflow path avoids abrupt internal turns and supports low component pressure drop.

Large filter and coil face areas improve service life and moisture separation.

Full-height side doors make each treatment section independently accessible.

Section lengths can be adjusted for coil access, sound attenuation and building column spacing.

مخاوف المنتج للعملاء

Long floor-mounted equipment must balance low pressure drop with plant-room access, shipping limits and service clearances.

High coil face velocity carries condensate into the downstream fan section.A wider coil face and adequate service plenum reduce velocity and allow drainage.
One continuous casing cannot pass around plant-room columns or through delivery openings.Bolted shipping sections reassemble on a continuous aligned base frame.
Filters can only be changed from the wrong side of the plant room.Service handing and door positions are selected before manufacture.
A short discharge plenum creates uneven fan outlet velocity at the duct connection.A sized discharge section provides pressure recovery and a uniform duct interface.

تطبيقات نموذجية

Cleanroom mechanical roomsPharmaceutical manufacturing HVACLaboratory air treatmentHospital supply-air systemsIndustrial clean facilities

المعلمات الفنية

Representative construction data for a floor-mounted horizontal AHU are provided below.

المواد الأساسيةPolyurethane foam or mineral-wool insulation in double-skin panels
سمك اللوحة40–70 mm insulated casing
العرض الفعال900–4000 mm nominal unit width
الحد الأقصى الطولUp to 15000 mm in bolted horizontal shipping sections
الصلب يواجه سمك0.6–1.0 mm inner and outer panel skins
الكثافة الأساسية40–43 kg/m³ polyurethane or 90–120 kg/m³ mineral wool
الموصلية الحرارية0.022–0.040 W/(m·K) depending on insulation
إنهاء السطحPowder-coated galvanized outer skin with galvanized or stainless inner skin
نوع المشتركThermal-break frame with gasketed panels and bolted aligned base sections
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Draw-through or blow-through arrangementSingle fan, twin fan or fan-wall sectionTop, side or end duct connectionsSound attenuator and discharge plenum modules

Planning a Horizontal Air Handling Unit specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا