A framed six-element resistance heater bank that adds controlled sensible heat to cleanroom supply air using robust finned tubular elements.
  • Six Protected Heating Elements
  • High Surface-Area Fins
  • Fast Sensible Heating
  • Replaceable Individual Elements
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

Six metal-sheathed resistance elements are fitted with continuous fins and supported in a rigid stainless frame. The enlarged surface area spreads electric heat into the passing air at a lower sheath loading than an exposed wire coil. Ceramic terminal insulators and a side junction box isolate power connections from the airstream, while the modular layout allows one element to be replaced without discarding the full bank.

الخصائص الرئيسية

Metal-sheathed elements protect the resistance conductor from direct contact with the air stream.

Continuous fins increase convection area and distribute heat across the full face of the bank.

Six independently terminated elements permit staged power control and balanced three-phase loading.

A removable junction cover gives direct access to ceramic terminals and individual element connections.

مخاوف المنتج للعملاء

Electric air heating must provide uniform temperature rise without overheated wire sections or inaccessible terminals.

Exposed resistance wire is vulnerable to contamination and physical damage.A stainless metal sheath encloses each resistance conductor before heat reaches the fins.
Uneven airflow creates local element overheating.Six evenly spaced finned elements spread watt density across the full heater face.
One failed element forces replacement of the complete heater.Each finned element is individually terminated and removable from the support frame.
Electrical terminals are difficult to inspect inside an AHU section.The external side junction box groups insulated connections outside the active airflow path.

تطبيقات نموذجية

Cleanroom AHU preheat sectionsLow-temperature supply-air heatingLaboratory make-up air unitsDrying and tempering modulesStandby heat for hydronic coil systems

المعلمات الفنية

Typical physical construction for a six-element finned-tubular heater bank is summarized below.

المواد الأساسيةIncoloy or stainless tubular elements with nickel-chromium resistance wire and magnesium-oxide insulation
سمك اللوحة1.5-2.5 mm stainless support-frame thickness
العرض الفعال400-1600 mm active heater face width
الحد الأقصى الطولUp to 2200 mm element bank length
الصلب يواجه سمك1.2-2.0 mm stainless junction-box sheet
الكثافة الأساسيةApproximately 2200-3000 kg/m³ for compacted magnesium-oxide element insulation
الموصلية الحراريةApproximately 20-30 W/(m·K) for compacted magnesium-oxide insulation
إنهاء السطحNatural stainless or passivated Incoloy sheath with metallic fins
نوع المشتركBolted six-element frame with threaded terminal studs and ceramic insulators
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Stainless steel or Incoloy element sheathSingle-stage, multi-stage or SCR power controlHigh-limit cutout and airflow interlockCustom frame dimensions and terminal-box orientation