Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Bilik Bersih HVAC dan Peralatan Pengendalian Udara

Pemanas udara elektrik Finned-tubular

A framed six-element resistance heater bank that adds controlled sensible heat to cleanroom supply air using robust finned tubular elements.
  • Six Protected Heating Elements
  • High Surface-Area Fins
  • Fast Sensible Heating
  • Replaceable Individual Elements
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

Six metal-sheathed resistance elements are fitted with continuous fins and supported in a rigid stainless frame. The enlarged surface area spreads electric heat into the passing air at a lower sheath loading than an exposed wire coil. Ceramic terminal insulators and a side junction box isolate power connections from the airstream, while the modular layout allows one element to be replaced without discarding the full bank.

Ciri-ciri Utama

Metal-sheathed elements protect the resistance conductor from direct contact with the air stream.

Continuous fins increase convection area and distribute heat across the full face of the bank.

Six independently terminated elements permit staged power control and balanced three-phase loading.

A removable junction cover gives direct access to ceramic terminals and individual element connections.

Kebimbangan Produk Pelanggan

Electric air heating must provide uniform temperature rise without overheated wire sections or inaccessible terminals.

Exposed resistance wire is vulnerable to contamination and physical damage.A stainless metal sheath encloses each resistance conductor before heat reaches the fins.
Uneven airflow creates local element overheating.Six evenly spaced finned elements spread watt density across the full heater face.
One failed element forces replacement of the complete heater.Each finned element is individually terminated and removable from the support frame.
Electrical terminals are difficult to inspect inside an AHU section.The external side junction box groups insulated connections outside the active airflow path.

Permohonan yang biasa

Cleanroom AHU preheat sectionsLow-temperature supply-air heatingLaboratory make-up air unitsDrying and tempering modulesStandby heat for hydronic coil systems

Parameter teknikal

Typical physical construction for a six-element finned-tubular heater bank is summarized below.

Bahan TerasIncoloy or stainless tubular elements with nickel-chromium resistance wire and magnesium-oxide insulation
Ketebalan Panel1.5-2.5 mm stainless support-frame thickness
Lebar berkesan400-1600 mm active heater face width
Panjang maksimumUp to 2200 mm element bank length
Keluli Menghadapi Ketebalan1.2-2.0 mm stainless junction-box sheet
Ketumpatan terasApproximately 2200-3000 kg/m³ for compacted magnesium-oxide element insulation
Kekonduksian TermaApproximately 20-30 W/(m·K) for compacted magnesium-oxide insulation
Kemasan permukaanNatural stainless or passivated Incoloy sheath with metallic fins
Jenis BersatuBolted six-element frame with threaded terminal studs and ceramic insulators
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Stainless steel or Incoloy element sheathSingle-stage, multi-stage or SCR power controlHigh-limit cutout and airflow interlockCustom frame dimensions and terminal-box orientation

Planning a Finned-Tubular Electric Air Heater specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami