وحدة تصفية مروحة مقاومة للانفجار
- Non-Sparking Blower Assembly
- Cast-Metal Motor Enclosure
- Sealed Junction Box and Conduit
- Bonded Grounding Path
مقدمة المنتج
The explosion-proof fan filter unit isolates electrical and rotating ignition sources with a heavy cast-metal motor enclosure, bolted junction box, rigid conduit and sealed fittings. A non-sparking impeller moves air through the prefilter and final filter, while a dedicated bonding strap connects the casing and metal prefilter frame to ground. The reinforced stainless or rolled-steel plenum supports the heavier drive assembly and uses a baffled diffuser to distribute airflow. Electrical voltage, enclosure construction and hazardous-area suitability are selected to match the intended process environment.
الخصائص الرئيسية
Bolted cast-metal junction hardware contains electrical terminations and connects through rigid sealed conduit.
A visible bonding strap links removable metal filter components to the grounded FFU casing.
The reinforced frame carries the concentrated motor load without distorting the filter seal or ceiling flange.
مخاوف المنتج للعملاء
A hazardous clean area must control particles while preventing the fan, wiring and removable prefilter from introducing an avoidable ignition source.
تطبيقات نموذجية
المعلمات الفنية
Typical construction ranges for a hazardous-duty explosion-proof fan filter unit are listed below.
| المواد الأساسية | Reinforced stainless or powder-coated steel plenum, non-sparking centrifugal impeller, cast-metal motor enclosure and micro-glass HEPA or ULPA filter |
|---|---|
| سمك اللوحة | 450-550 mm overall module depth including the hazardous-duty motor assembly |
| العرض الفعال | 575-610 mm nominal module width |
| الحد الأقصى الطول | Up to 1220 mm standard module length |
| الصلب يواجه سمك | 1.2-2.0 mm reinforced stainless or powder-coated rolled-steel housing sheet |
| الكثافة الأساسية | Approximately 90-120 kg/m³ nominal compacted density of the final-filter pack used in the explosion-protected FFU assembly |
| الموصلية الحرارية | Approximately 0.035-0.043 W/(m·K) for the dry final-filter pack used in the explosion-protected FFU assembly |
| إنهاء السطح | Brushed stainless steel or chemically resistant powder coating with grounded bare-metal bonding points |
| نوع المشترك | Reinforced ceiling flange with bonded perimeter gasket and room-side gel-seal or compression-seal filter interface |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Explosion-Proof Fan Filter Unit specification?