หน่วยกรองพัดลมป้องกันการระเบิด หน่วยกรองพัดลม
- Non-Sparking Blower Assembly
- Cast-Metal Motor Enclosure
- Sealed Junction Box and Conduit
- Bonded Grounding Path
การแนะนําสินค้า
The explosion-proof fan filter unit isolates electrical and rotating ignition sources with a heavy cast-metal motor enclosure, bolted junction box, rigid conduit and sealed fittings. A non-sparking impeller moves air through the prefilter and final filter, while a dedicated bonding strap connects the casing and metal prefilter frame to ground. The reinforced stainless or rolled-steel plenum supports the heavier drive assembly and uses a baffled diffuser to distribute airflow. Electrical voltage, enclosure construction and hazardous-area suitability are selected to match the intended process environment.
คุณสมบัติที่สําคัญ
Bolted cast-metal junction hardware contains electrical terminations and connects through rigid sealed conduit.
A visible bonding strap links removable metal filter components to the grounded FFU casing.
The reinforced frame carries the concentrated motor load without distorting the filter seal or ceiling flange.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
A hazardous clean area must control particles while preventing the fan, wiring and removable prefilter from introducing an avoidable ignition source.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
Typical construction ranges for a hazardous-duty explosion-proof fan filter unit are listed below.
| วัสดุหลัก | Reinforced stainless or powder-coated steel plenum, non-sparking centrifugal impeller, cast-metal motor enclosure and micro-glass HEPA or ULPA filter |
|---|---|
| ความหนาของแผง | 450-550 mm overall module depth including the hazardous-duty motor assembly |
| ความกว้างที่มีประสิทธิภาพ | 575-610 mm nominal module width |
| ความยาวสูงสุด | Up to 1220 mm standard module length |
| ความหนาของเหล็กหันหน้า | 1.2-2.0 mm reinforced stainless or powder-coated rolled-steel housing sheet |
| ความหนาแน่นหลัก | Approximately 90-120 kg/m³ nominal compacted density of the final-filter pack used in the explosion-protected FFU assembly |
| การนําความร้อน | Approximately 0.035-0.043 W/(m·K) for the dry final-filter pack used in the explosion-protected FFU assembly |
| เสร็จสิ้นพื้นผิว | Brushed stainless steel or chemically resistant powder coating with grounded bare-metal bonding points |
| ประเภทร่วม | Reinforced ceiling flange with bonded perimeter gasket and room-side gel-seal or compression-seal filter interface |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Planning a Explosion-Proof Fan Filter Unit specification?
ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

ภาษาอังกฤษ
ภาษาเยอรมัน
ภาษาอาหรับ
ฝรั่งเศส
ภาษาอินโดนีเซีย
ภาษาญี่ปุ่น
ภาษาเกาหลี
ภาษามาเลย์
ภาษาโปรตุเกส
ภาษารัสเซีย
ภาษาสเปน
ภาษาไทยปัจจุบัน
ภาษาตุรกี
ภาษาเวียดนาม