موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

استشعار الغاز القابل للاحتراق

A fixed percent-LEL gas detector that monitors flammable gas or vapor accumulation and activates local and remote alarms before hazardous concentration develops.
  • Percent-LEL Monitoring
  • Catalytic or Infrared Sensor
  • Local Warning and Alarm
  • Remote Shutdown Outputs
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The fixed combustible gas detector measures a selected flammable gas using a catalytic bead or infrared absorption sensor. Its display presents concentration as a percentage of the lower explosive limit, while independent warning and alarm thresholds can start ventilation, isolate gas supply or activate evacuation indication. A flame-resistant sintered inlet protects the sensing element while allowing gas diffusion. Infrared versions are well suited to many hydrocarbons and resist poisoning mechanisms that can affect catalytic elements; catalytic versions provide broad combustible-gas response where oxygen is present.

الخصائص الرئيسية

Percent-LEL indication communicates flammable concentration relative to the gas hazard threshold.

Catalytic and infrared sensing choices address different gas families and operating conditions.

A sintered metal inlet protects the active element while permitting ambient gas diffusion.

Alarm relays and analog or digital outputs support ventilation and gas-isolation actions.

مخاوف المنتج للعملاء

Combustible gas detection must account for the target gas, sensor technology, oxygen availability and potential catalyst poisons.

A catalytic sensor is exposed to silicone or sulfur compounds that reduce sensitivity.Sensor-technology selection and planned response checks address known catalyst-poison risks.
The chosen infrared sensor does not respond to the target gas family.The optical wavelength and calibration gas are matched to the expected combustible compound.
A gas leak reaches the ceiling or floor before the detector location.Detector height follows gas density, release pressure and room-air movement.
The local detector alarms but ventilation or gas shutoff does not respond.Dedicated relay outputs link warning and alarm thresholds to engineered control actions.

تطبيقات نموذجية

Solvent-use cleanroom supportHydrogen utility roomsFlammable gas cabinetsBattery and process equipment areas

المعلمات الفنية

Typical construction values for a fixed combustible gas detector are listed below.

المواد الأساسيةCatalytic bead or infrared optical cell in coated aluminum transmitter with stainless sintered sensor inlet
سمك اللوحة80-140 mm detector depth
العرض الفعال130-220 mm transmitter width
الحد الأقصى الطولUp to 320 mm overall detector height
الصلب يواجه سمك0.8-1.2 mm stainless guard and mounting hardware
الكثافة الأساسية2650-2750 kg/m³ for aluminum transmitter body
الموصلية الحرارية150-220 W/(m·K) for aluminum enclosure material
إنهاء السطحSafety-yellow or gray coated aluminum body with black display and red alarm beacon
نوع المشتركThreaded sintered sensing head with sealed conduit entries and removable relay terminals
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Catalytic or infrared sensorTarget-gas calibrationLocal display and beaconRelay, analog and digital outputs