클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

가연성 가스 센서

A fixed percent-LEL gas detector that monitors flammable gas or vapor accumulation and activates local and remote alarms before hazardous concentration develops.
  • Percent-LEL Monitoring
  • Catalytic or Infrared Sensor
  • Local Warning and Alarm
  • Remote Shutdown Outputs
견적 요청 제품 찾아보기

상품 소개

The fixed combustible gas detector measures a selected flammable gas using a catalytic bead or infrared absorption sensor. Its display presents concentration as a percentage of the lower explosive limit, while independent warning and alarm thresholds can start ventilation, isolate gas supply or activate evacuation indication. A flame-resistant sintered inlet protects the sensing element while allowing gas diffusion. Infrared versions are well suited to many hydrocarbons and resist poisoning mechanisms that can affect catalytic elements; catalytic versions provide broad combustible-gas response where oxygen is present.

주요 기능

Percent-LEL indication communicates flammable concentration relative to the gas hazard threshold.

Catalytic and infrared sensing choices address different gas families and operating conditions.

A sintered metal inlet protects the active element while permitting ambient gas diffusion.

Alarm relays and analog or digital outputs support ventilation and gas-isolation actions.

고객 제품 관심사

Combustible gas detection must account for the target gas, sensor technology, oxygen availability and potential catalyst poisons.

A catalytic sensor is exposed to silicone or sulfur compounds that reduce sensitivity.Sensor-technology selection and planned response checks address known catalyst-poison risks.
The chosen infrared sensor does not respond to the target gas family.The optical wavelength and calibration gas are matched to the expected combustible compound.
A gas leak reaches the ceiling or floor before the detector location.Detector height follows gas density, release pressure and room-air movement.
The local detector alarms but ventilation or gas shutoff does not respond.Dedicated relay outputs link warning and alarm thresholds to engineered control actions.

일반적인 응용 프로그램

Solvent-use cleanroom supportHydrogen utility roomsFlammable gas cabinetsBattery and process equipment areas

기술 매개변수

Typical construction values for a fixed combustible gas detector are listed below.

핵심 재료Catalytic bead or infrared optical cell in coated aluminum transmitter with stainless sintered sensor inlet
패널 두께80-140 mm detector depth
유효 폭130-220 mm transmitter width
최대 길이Up to 320 mm overall detector height
강철 면면 두께0.8-1.2 mm stainless guard and mounting hardware
코어 밀도2650-2750 kg/m³ for aluminum transmitter body
열전도도 (Thermal Conductivity)150-220 W/(m·K) for aluminum enclosure material
표면 마무리Safety-yellow or gray coated aluminum body with black display and red alarm beacon
접합 유형Threaded sintered sensing head with sealed conduit entries and removable relay terminals
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Catalytic or infrared sensorTarget-gas calibrationLocal display and beaconRelay, analog and digital outputs

Planning a Combustible Gas Sensor specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기