可燃性ガスセンサー

A fixed percent-LEL gas detector that monitors flammable gas or vapor accumulation and activates local and remote alarms before hazardous concentration develops.
  • Percent-LEL Monitoring
  • Catalytic or Infrared Sensor
  • Local Warning and Alarm
  • Remote Shutdown Outputs
見積もりリクエスト 製品案内

商品紹介

The fixed combustible gas detector measures a selected flammable gas using a catalytic bead or infrared absorption sensor. Its display presents concentration as a percentage of the lower explosive limit, while independent warning and alarm thresholds can start ventilation, isolate gas supply or activate evacuation indication. A flame-resistant sintered inlet protects the sensing element while allowing gas diffusion. Infrared versions are well suited to many hydrocarbons and resist poisoning mechanisms that can affect catalytic elements; catalytic versions provide broad combustible-gas response where oxygen is present.

主要な特徴

Percent-LEL indication communicates flammable concentration relative to the gas hazard threshold.

Catalytic and infrared sensing choices address different gas families and operating conditions.

A sintered metal inlet protects the active element while permitting ambient gas diffusion.

Alarm relays and analog or digital outputs support ventilation and gas-isolation actions.

お客様の製品に関する懸念事項

Combustible gas detection must account for the target gas, sensor technology, oxygen availability and potential catalyst poisons.

A catalytic sensor is exposed to silicone or sulfur compounds that reduce sensitivity.Sensor-technology selection and planned response checks address known catalyst-poison risks.
The chosen infrared sensor does not respond to the target gas family.The optical wavelength and calibration gas are matched to the expected combustible compound.
A gas leak reaches the ceiling or floor before the detector location.Detector height follows gas density, release pressure and room-air movement.
The local detector alarms but ventilation or gas shutoff does not respond.Dedicated relay outputs link warning and alarm thresholds to engineered control actions.

典型的な用途

Solvent-use cleanroom supportHydrogen utility roomsFlammable gas cabinetsBattery and process equipment areas

技術的なパラメータ

Typical construction values for a fixed combustible gas detector are listed below.

コア材料Catalytic bead or infrared optical cell in coated aluminum transmitter with stainless sintered sensor inlet
パネルの厚さ80-140 mm detector depth
有効幅130-220 mm transmitter width
最大長さUp to 320 mm overall detector height
鋼鉄の厚さを直面する0.8-1.2 mm stainless guard and mounting hardware
コア密度2650-2750 kg/m³ for aluminum transmitter body
熱伝導率150-220 W/(m·K) for aluminum enclosure material
表面仕上げSafety-yellow or gray coated aluminum body with black display and red alarm beacon
ジョイントタイプThreaded sintered sensing head with sealed conduit entries and removable relay terminals
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Catalytic or infrared sensorTarget-gas calibrationLocal display and beaconRelay, analog and digital outputs