غرفة نظيفة مرنة أنبوب الهواء

A bendable reinforced air duct for short cleanroom terminal connections where rigid ductwork cannot absorb alignment or equipment movement.
  • Tight-Bend Connection
  • Spring-Wire Reinforcement
  • Smooth Flexible Liner
  • Insulated Option Available
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

Cleanroom flexible duct uses a continuous polymer or coated-fabric liner supported by a corrosion-resistant spring-wire helix. It is intended for short final connections between rigid duct branches and diffusers, fan terminals or movable equipment, not as a substitute for long straight mains. An optional glass-fiber blanket and outer vapor jacket limit heat gain and condensation on conditioned-air runs. Correctly extended installation minimizes internal corrugation, while stainless clamps and foil tape secure each end to a smooth metal collar.

الخصائص الرئيسية

A spring-wire helix maintains the circular bore through controlled bends and minor alignment changes.

The continuous liner avoids longitudinal metal seams and accommodates equipment vibration.

Insulated versions combine a thermal blanket with a sealed external vapor jacket.

Short standard lengths discourage excessive sag and the pressure loss caused by compressed duct.

مخاوف المنتج للعملاء

Flexible duct only performs well when it is kept short, fully extended and supported without sharp kinks or compressed coils.

A rigid branch does not align precisely with the terminal collar.The flexible section absorbs the final offset without multiple hard elbows.
Compressed duct corrugations create unexpectedly high pressure loss.The liner is pulled taut and cut to the shortest practical connection length.
Unsupported duct sags above the ceiling and reduces its internal area.Wide straps at close intervals support the full diameter without pinching the jacket.
Cold-air connections sweat where the vapor jacket is punctured.Insulation and outer jacket are closed continuously around both collars with compatible tape.

تطبيقات نموذجية

HEPA terminal-box connectionsCeiling diffuser branchesFan-powered terminal outletsVibration-isolated equipment linksShort return-air connections

المعلمات الفنية

Typical construction ranges for reinforced flexible HVAC duct used at cleanroom terminals are shown below.

المواد الأساسيةCoated fiberglass fabric or multilayer polymer liner with corrosion-resistant spring-steel helix
سمك اللوحة0.10–0.30 mm flexible liner wall
العرض الفعال75–500 mm nominal internal diameter
الحد الأقصى الطول7500 mm supplied length; short installed connections recommended
الصلب يواجه سمك0.8–1.5 mm spring-wire diameter, depending on duct size
الكثافة الأساسية16–24 kg/m³ optional glass-fiber insulation blanket
الموصلية الحرارية0.036–0.043 W/(m·K) for insulated versions
إنهاء السطحSmooth inner liner with reinforced silver vapor-barrier outer jacket
نوع المشتركClamped overlap on rigid collar with foil tape and sealed outer vapor jacket
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Uninsulated or insulated constructionR4.2, R6 or R8 thermal blanketLow-smoke polymer or coated-fabric linerStainless clamps and cleanroom-compatible sealing tape