Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Hava Dağıtım Sistemleri / Cleanroom Flexible Air Duct
Temiz Oda Hava Dağıtım Sistemleri

Temiz Oda Esnek Hava Kanalları

A bendable reinforced air duct for short cleanroom terminal connections where rigid ductwork cannot absorb alignment or equipment movement.
  • Tight-Bend Connection
  • Spring-Wire Reinforcement
  • Smooth Flexible Liner
  • Insulated Option Available
Alıntı isteği Browse ürünleri

Ürün tanıtımı

Cleanroom flexible duct uses a continuous polymer or coated-fabric liner supported by a corrosion-resistant spring-wire helix. It is intended for short final connections between rigid duct branches and diffusers, fan terminals or movable equipment, not as a substitute for long straight mains. An optional glass-fiber blanket and outer vapor jacket limit heat gain and condensation on conditioned-air runs. Correctly extended installation minimizes internal corrugation, while stainless clamps and foil tape secure each end to a smooth metal collar.

Ana Özellikler

A spring-wire helix maintains the circular bore through controlled bends and minor alignment changes.

The continuous liner avoids longitudinal metal seams and accommodates equipment vibration.

Insulated versions combine a thermal blanket with a sealed external vapor jacket.

Short standard lengths discourage excessive sag and the pressure loss caused by compressed duct.

Müşteri Ürün Sorunları

Flexible duct only performs well when it is kept short, fully extended and supported without sharp kinks or compressed coils.

A rigid branch does not align precisely with the terminal collar.The flexible section absorbs the final offset without multiple hard elbows.
Compressed duct corrugations create unexpectedly high pressure loss.The liner is pulled taut and cut to the shortest practical connection length.
Unsupported duct sags above the ceiling and reduces its internal area.Wide straps at close intervals support the full diameter without pinching the jacket.
Cold-air connections sweat where the vapor jacket is punctured.Insulation and outer jacket are closed continuously around both collars with compatible tape.

Tipik uygulamalar

HEPA terminal-box connectionsCeiling diffuser branchesFan-powered terminal outletsVibration-isolated equipment linksShort return-air connections

Teknik parametreler

Typical construction ranges for reinforced flexible HVAC duct used at cleanroom terminals are shown below.

Temel malzemelerCoated fiberglass fabric or multilayer polymer liner with corrosion-resistant spring-steel helix
Panel kalınlığı0.10–0.30 mm flexible liner wall
Effective Width (Etkili Genişlik)75–500 mm nominal internal diameter
Maksimum uzunluk7500 mm supplied length; short installed connections recommended
Çelik yüz yüze kalınlığı0.8–1.5 mm spring-wire diameter, depending on duct size
Core Density (Çekirdek Yoğunluğu)16–24 kg/m³ optional glass-fiber insulation blanket
Termal İletkenlik0.036–0.043 W/(m·K) for insulated versions
Yüzey bitirmeSmooth inner liner with reinforced silver vapor-barrier outer jacket
Ortak tipClamped overlap on rigid collar with foil tape and sealed outer vapor jacket
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Uninsulated or insulated constructionR4.2, R6 or R8 thermal blanketLow-smoke polymer or coated-fabric linerStainless clamps and cleanroom-compatible sealing tape

Planning a Cleanroom Flexible Air Duct specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim