موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

نظام إدارة مبنى الغرف النظيفة

A centralized building-management platform that combines cleanroom HVAC status, pressure cascades, environmental trends, alarms and utility data in one operator interface.
  • Unified Cleanroom Dashboard
  • Open Protocol Integration
  • Alarm and Trend Management
  • Multi-Zone HVAC Supervision
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The cleanroom BMS links field controllers, room sensors, meters and equipment interfaces through an industrial control network. Operator workstations present floor plans, live values, alarms, schedules and historical trends without forcing technicians to visit each panel. Pressure-critical rooms can be organized by suite, while AHUs, terminal airflow devices and utilities retain their own control loops. The system architecture supports segmented networks and role-based access so facility, engineering and quality teams can work from the same verified operating data.

الخصائص الرئيسية

Graphical floor plans show live room conditions and equipment status by cleanroom zone.

BACnet, Modbus and OPC interfaces connect field controllers, sensors and third-party subsystems.

Time-stamped alarms and trends help operators trace excursions back to the affected asset.

Schedules, setpoint limits and energy dashboards coordinate occupied and standby operation.

مخاوف المنتج للعملاء

A cleanroom campus needs one operational view without weakening the fast local control loops that maintain each pressure and airflow relationship.

Operators must check separate HVAC, room-pressure and utility screens.A unified workstation maps the subsystems into one room-by-room navigation structure.
Alarm floods hide the first condition that caused a cascade of warnings.Priority, delay, acknowledgement and event chronology separate initiating alarms from consequences.
Trend data from different controllers use inconsistent time references.Central time synchronization and historian collection align measurements on one timeline.
Unrestricted setpoint changes can destabilize validated room relationships.Role-based permissions and bounded setpoint commands limit changes to authorized operating ranges.

تطبيقات نموذجية

Pharmaceutical cleanroom campusesBiotechnology production suitesMedical-device manufacturingSemiconductor controlled facilities

المعلمات الفنية

Typical construction values for the cleanroom BMS control cabinet and operator hardware are shown below.

المواد الأساسيةPowder-coated steel control enclosure with FR-4 controller boards and copper bus components
سمك اللوحة200-400 mm cabinet depth
العرض الفعال600-1200 mm enclosure width
الحد الأقصى الطولUp to 2200 mm enclosure height
الصلب يواجه سمك1.2-2.0 mm powder-coated steel enclosure panels
الكثافة الأساسية7800-8050 kg/m³ for steel structural parts
الموصلية الحرارية45-60 W/(m·K) for steel cabinet components
إنهاء السطحLight-gray textured powder coating with labeled operator controls
نوع المشتركGasketed modular cabinet with DIN-rail terminals and segregated network compartments
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Redundant supervisory serverHistorian and reporting workstationBACnet and Modbus integrationWeb and mobile operator clients

Planning a Cleanroom Building Management System specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat