Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Aydınlatma ve Elektrik Ekipmanları

Kesintisiz güç kaynağı

An online UPS system that conditions incoming power and maintains critical cleanroom controls through short supply interruptions.
  • Double-Conversion Power Path
  • Modular Battery Backup
  • Automatic Static Bypass
  • Networked Battery Monitoring
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The UPS rectifies the incoming supply to a DC bus and continuously regenerates a stable AC output through its inverter. Rechargeable battery modules support the DC bus when utility power is lost, while an automatic static bypass provides an alternate path for overload or internal fault conditions. A local color display and network card report load, runtime, battery health and alarm state.

Ana Özellikler

Continuous conversion isolates critical loads from common voltage variation.

Hot-serviceable battery modules allow capacity to be matched to required runtime.

The static bypass transfers the load without a mechanical switching delay.

A front display presents load percentage, battery condition and active alarms.

Network monitoring sends power events to the facility management system.

Müşteri Ürün Sorunları

Backup power must preserve control and data continuity while making battery condition and remaining runtime visible before an outage occurs.

A brief utility dip restarts controllers and interrupts batch records.The continuously energized inverter maintains a stable output through input disturbances.
Battery capacity degrades unnoticed between maintenance visits.Monitored battery modules report health and replacement conditions.
UPS maintenance requires a complete load shutdown.A static and optional maintenance bypass provides an alternate supply path.
Operators overload the unit as new equipment is connected.The display and network interface show real-time load headroom and alarm thresholds.

Tipik uygulamalar

Cleanroom control systemsEnvironmental monitoring serversAccess and interlock controlsCritical laboratory instruments

Teknik parametreler

Typical configurable construction ranges for an uninterruptible power supply are listed below.

Temel malzemelerPowder-coated steel rack or tower enclosure with rectifier, inverter, static bypass, control electronics and battery modules
Panel kalınlığı450-900 mm cabinet or rack depth
Effective Width (Etkili Genişlik)440-800 mm enclosure width
Maksimum uzunlukUp to 2000 mm overall cabinet height
Çelik yüz yüze kalınlığı1.0-1.8 mm powder-coated steel chassis and access panels
Core Density (Çekirdek Yoğunluğu)Approximately 7850 kg/m³ for the structural steel enclosure
Termal İletkenlik45-60 W/(m·K) for the carbon-steel chassis
Yüzey bitirmeWhite, light-grey or black powder-coated cabinet with color LCD and green/amber/red status indicators
Ortak tipModular rack or tower chassis with plug-in power/battery modules, protected terminals and bypass connection
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Single- or three-phase input/outputLithium-ion or valve-regulated lead-acid batteriesExternal maintenance bypassNetwork management card

Planning a Uninterruptible Power Supply specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim