An online UPS system that conditions incoming power and maintains critical cleanroom controls through short supply interruptions.
  • Double-Conversion Power Path
  • Modular Battery Backup
  • Automatic Static Bypass
  • Networked Battery Monitoring
見積もりリクエスト 製品案内

商品紹介

The UPS rectifies the incoming supply to a DC bus and continuously regenerates a stable AC output through its inverter. Rechargeable battery modules support the DC bus when utility power is lost, while an automatic static bypass provides an alternate path for overload or internal fault conditions. A local color display and network card report load, runtime, battery health and alarm state.

主要な特徴

Continuous conversion isolates critical loads from common voltage variation.

Hot-serviceable battery modules allow capacity to be matched to required runtime.

The static bypass transfers the load without a mechanical switching delay.

A front display presents load percentage, battery condition and active alarms.

Network monitoring sends power events to the facility management system.

お客様の製品に関する懸念事項

Backup power must preserve control and data continuity while making battery condition and remaining runtime visible before an outage occurs.

A brief utility dip restarts controllers and interrupts batch records.The continuously energized inverter maintains a stable output through input disturbances.
Battery capacity degrades unnoticed between maintenance visits.Monitored battery modules report health and replacement conditions.
UPS maintenance requires a complete load shutdown.A static and optional maintenance bypass provides an alternate supply path.
Operators overload the unit as new equipment is connected.The display and network interface show real-time load headroom and alarm thresholds.

典型的な用途

Cleanroom control systemsEnvironmental monitoring serversAccess and interlock controlsCritical laboratory instruments

技術的なパラメータ

Typical configurable construction ranges for an uninterruptible power supply are listed below.

コア材料Powder-coated steel rack or tower enclosure with rectifier, inverter, static bypass, control electronics and battery modules
パネルの厚さ450-900 mm cabinet or rack depth
有効幅440-800 mm enclosure width
最大長さUp to 2000 mm overall cabinet height
鋼鉄の厚さを直面する1.0-1.8 mm powder-coated steel chassis and access panels
コア密度Approximately 7850 kg/m³ for the structural steel enclosure
熱伝導率45-60 W/(m·K) for the carbon-steel chassis
表面仕上げWhite, light-grey or black powder-coated cabinet with color LCD and green/amber/red status indicators
ジョイントタイプModular rack or tower chassis with plug-in power/battery modules, protected terminals and bypass connection
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Single- or three-phase input/outputLithium-ion or valve-regulated lead-acid batteriesExternal maintenance bypassNetwork management card

Planning a Uninterruptible Power Supply specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat