상품 소개
The UPS rectifies the incoming supply to a DC bus and continuously regenerates a stable AC output through its inverter. Rechargeable battery modules support the DC bus when utility power is lost, while an automatic static bypass provides an alternate path for overload or internal fault conditions. A local color display and network card report load, runtime, battery health and alarm state.
주요 기능
Hot-serviceable battery modules allow capacity to be matched to required runtime.
The static bypass transfers the load without a mechanical switching delay.
A front display presents load percentage, battery condition and active alarms.
Network monitoring sends power events to the facility management system.
고객 제품 관심사
Backup power must preserve control and data continuity while making battery condition and remaining runtime visible before an outage occurs.
A brief utility dip restarts controllers and interrupts batch records.The continuously energized inverter maintains a stable output through input disturbances.
Battery capacity degrades unnoticed between maintenance visits.Monitored battery modules report health and replacement conditions.
UPS maintenance requires a complete load shutdown.A static and optional maintenance bypass provides an alternate supply path.
Operators overload the unit as new equipment is connected.The display and network interface show real-time load headroom and alarm thresholds.
일반적인 응용 프로그램
Cleanroom control systemsEnvironmental monitoring serversAccess and interlock controlsCritical laboratory instruments
기술 매개변수
Typical configurable construction ranges for an uninterruptible power supply are listed below.
| 핵심 재료 | Powder-coated steel rack or tower enclosure with rectifier, inverter, static bypass, control electronics and battery modules |
|---|---|
| 패널 두께 | 450-900 mm cabinet or rack depth |
| 유효 폭 | 440-800 mm enclosure width |
| 최대 길이 | Up to 2000 mm overall cabinet height |
| 강철 면면 두께 | 1.0-1.8 mm powder-coated steel chassis and access panels |
| 코어 밀도 | Approximately 7850 kg/m³ for the structural steel enclosure |
| 열전도도 (Thermal Conductivity) | 45-60 W/(m·K) for the carbon-steel chassis |
| 표면 마무리 | White, light-grey or black powder-coated cabinet with color LCD and green/amber/red status indicators |
| 접합 유형 | Modular rack or tower chassis with plug-in power/battery modules, protected terminals and bypass connection |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Single- or three-phase input/outputLithium-ion or valve-regulated lead-acid batteriesExternal maintenance bypassNetwork management card
Planning a Uninterruptible Power Supply specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.