A conditioned-steam assembly that separates condensate, modulates plant steam and disperses dry vapor through a preheated stainless duct lance.
  • Dry Plant-Steam Conditioning
  • Cyclonic Moisture Separation
  • Modulating Control Valve
  • Preheated Dispersion Lance
Alıntı isteği Browse ürünleri

Ürün tanıtımı

Plant steam first enters a vertical separator where velocity changes and internal baffles remove entrained condensate. A modulating valve meters the dry steam to a stainless distribution lance, while a tracer circuit warms the lance to reduce internal condensation. Steam traps continuously drain the separator and tracer so only conditioned vapor reaches the airstream.

Ana Özellikler

Cyclonic and baffle separation removes liquid droplets before the control valve and lance.

A modulating valve adjusts plant-steam flow directly to humidity demand without a local electric boiler.

The preheated stainless lance limits condensation at the dispersion orifices during modulation.

Independent separator and tracer traps maintain continuous drainage and reduce waterhammer risk.

Müşteri Ürün Sorunları

Direct injection is effective only when plant steam is dry, accurately metered and dispersed before duct surfaces can become wet.

Wet plant steam spits condensate from duct nozzles.The vertical separator and continuous trap remove liquid before steam enters the dispersion lance.
An unheated lance condenses steam at low output.A tracer circuit preheats the stainless lance and drains its condensate separately.
Short absorption distance wets downstream filters.One or more correctly sized lances distribute steam across the duct face in smaller jets.
A sticking valve causes humidity overshoot.A characterized modulating valve and matched actuator provide repeatable flow control.

Tipik uygulamalar

Large pharmaceutical air handlersHospital central-steam HVACIndustrial cleanroom make-up airLaboratory ventilation systemsHigh-capacity process-air humidification

Teknik parametreler

Representative construction ranges for a conditioned direct-steam humidifier are listed below.

Temel malzemelerAISI 304 or 316L stainless separator and preheated dispersion lance
Panel kalınlığı1.5-3.0 mm separator shell and lance wall thickness
Effective Width (Etkili Genişlik)300-3500 mm compatible duct width
Maksimum uzunlukUp to 4000 mm maximum multi-lance dispersion assembly length
Çelik yüz yüze kalınlığı1.5-3.0 mm stainless separator and lance construction
Core Density (Çekirdek Yoğunluğu)Approximately 7900-8000 kg/m³ for stainless wetted components
Termal İletkenlikApproximately 14-16 W/(m·K) for austenitic stainless steel
Yüzey bitirmePickled and passivated or mechanically polished stainless surfaces
Ortak tipFlanged or threaded steam inlet with compression-connected tracer and bolted duct-lance flange
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Single or multiple dispersion lancesAISI 304 or 316L wetted constructionElectric or pneumatic valve actuatorDifferent steam pressure, valve size and lance length